AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain

The AirTAC GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$197.61 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain

The GC60025AF2G is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one set, so compressed air is cleaned of water and particulate, held at a set working pressure, and carried with a fine oil mist to downstream equipment. This 600-size unit is fitted with a G1 (1 in) G-thread port, the largest port step in the G-series range. The filter element is the standard 40 um grade, the bowl drains automatically, and the regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi). An embedded square gauge with a psi scale is fitted so the set outlet pressure can be read directly.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, a choice of drain types (differential-pressure, automatic or manual), an optional 5 um filter grade (code W), gauge scale options, and G or NPT thread variants as order options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain Technical Specifications

ModelGC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain Is Used

factory

Main air preparation for a production hall ring main

Installed at the take-off point of a large plant air ring main, the three-unit set cleans, regulates and lubricates the supply feeding an entire work area, with the 1 in G-thread port matching the main line and the automatic drain handling condensate without daily attention.

conveyor_belt

Pneumatic drive air for a packaging and conveyor line

Mounted on the frame of a carton-forming and conveyor line, the set supplies clean, pressure-stable and oil-misted air to the cylinders and air motors that index, clamp and move product along the line, with the psi gauge giving operators a visible set-point.

engineering

Air supply to heavy pneumatic press and clamp tooling

Fitted ahead of a large pneumatic press or clamping fixture, the combination protects the tool's valves and cylinders from water and swarf, holds a steady working pressure for repeatable clamping force, and keeps the tool's air lubricated over long production runs.

Is the GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain the Right Station?

Start with the port and flow path: the 600 size carries the largest port in the G-series (1 in here, G thread), so match it to the main air line serving the machine or cell. Choose the drain to suit access: this unit has an automatic drain, which suits bowls mounted where regular manual draining is impractical; manual and differential-pressure drain versions are available in the family. The 40 um element is the standard grade; specify the W suffix if the application needs the 5 um option. The fitted square gauge reads in psi; MPa and bar scales are alternatives, and an external round gauge is optional.

Thread is G (BSPP) on this code; PT is the catalogue standard and NPT is also available as an order option, so confirm the thread your piping needs before ordering. A mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your air demand before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow number. Send us your air demand and line details and we will confirm the sizing against the datasheet curves on request before you order.

The A in the code GC60025AF2G selects the automatic drain, which expels collected condensate from the filter bowl without anyone opening it - useful where the unit is mounted in a hard-to-reach spot. The GC family also offers manual and differential-pressure drain versions if you prefer a different arrangement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC60025AF2G AirTAC F.R.L. 1 in G Thread, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025AF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.