verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60025ALC2G AirTAC F.R.L. Combination, G1 Port

The AirTAC GC60025ALC2G AirTAC F.R.L. Combination, G1 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$197.76 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC60025ALC2G AirTAC F.R.L. Combination, G1 Port

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one air-treatment set. This GC60025ALC2G is the size 600 unit with a G1 (1 in) port in G thread. The filter section carries the standard 40 um element with an automatic drain, so collected condensate is discharged without manual attention. The regulator is the low-pressure type and is fitted with an external round gauge scaled in psi; the lubricator feeds oil mist downstream to pneumatic tools and cylinders. At size 600, the bowls are aluminium alloy, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 5 um filter element option (code W), gauge scales in MPa, psi or bar, and PT (standard), G or NPT thread options. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application before ordering.

GC60025ALC2G AirTAC F.R.L. Combination, G1 Port Technical Specifications

ModelGC60025ALC2G AirTAC F.R.L. Combination, G1 Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60025ALC2G AirTAC F.R.L. Combination, G1 Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC60025ALC2G AirTAC F.R.L. Combination, G1 Port Is Used

factory

Automotive assembly plant air drops

Point-of-use treatment at 1 in air drops feeding assembly stations: the filter removes water and particulate, the low-pressure regulator holds a stable supply pressure to the tools, and the lubricator mists oil to air impact wrenches and nut runners.

conveyor_belt

Packaging line conveyor actuators

Feeding pneumatic pushers, clamps and stop gates on a packaging conveyor, where the automatic drain keeps condensate out of the valve manifold, the regulator sets the actuation pressure and the lubricator extends cylinder seal life.

valve

Pneumatic valve manifold supply on a process skid

Conditioning the supply to a bank of directional control valves on a process skid: clean, regulated, lubricated air protects valve spools and actuators, with the psi gauge giving operators a local pressure readout at the manifold.

Is the GC60025ALC2G AirTAC F.R.L. Combination, G1 Port the Right Station?

Start with the port and size: this unit is size 600 with a G1 (1 in) port, the largest step in the GC range - step down to 200/300/400 if your line runs smaller ports and lower air demand, and match the flow curve to your consumption rather than assuming from port size alone. The automatic drain on this configuration suits unattended or hard-to-reach installations; choose manual or differential-pressure drain if you prefer operator-controlled or pressure-differential discharge. The 40 um element is the standard grade; specify the W code for the 5 um element where finer particulate removal is needed. The fitted round gauge reads in psi; MPa and bar scales are available, and the embedded square gauge is the standard alternative. Thread is G here, with PT (standard) and NPT as order options. Flow is published as curves, not a single rating - send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC60025ALC2G AirTAC F.R.L. Combination, G1 Port FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your port size, working pressure and air consumption, and we will confirm the flow from the datasheet for this G1 (1 in) size 600 unit before you order.

The A code in GC60025ALC2G specifies an automatic drain on the filter bowl, which discharges collected condensate without operator attention - useful for unattended or elevated installations. The GC family also offers manual drain (M) and the differential-pressure drain as the default, so you can order the drain type that matches your maintenance routine.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC60025ALC2G AirTAC F.R.L. Combination, G1 Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025ALC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.