verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

The AirTAC GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$209.13 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

This GC600 series unit is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator, each doing its own job in one assembled set. The filter element is the fine 5 um grade (the standard element is 40 um; W on the code selects 5 um) with an automatic drain, so collected water is expelled without manual attention. The bowl on the filter section is aluminium alloy, as is standard for the 600 size. The regulator is the low-pressure type and carries a round pressure gauge reading in psi; a reverse/check valve is also fitted. The set is supplied with a mounting bracket and takes a G1 (1 in) port with G thread. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family is offered across the 200, 300, 400 and 600 sizes with a choice of ports, drain types, filter grades, gauges and thread options, so a configuration can be matched to the line it feeds. Flow figures for this series are published as curves rather than a single rated number; ask us and we will confirm the datasheet figures for your application on request.

GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port Technical Specifications

ModelGC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 5 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port Is Used

precision_manufacturing

Automated assembly cell with pneumatic grippers

Feeding a cell of pick-and-place grippers and clamps: the 5 um element protects the directional valves from fine particulate, the automatic drain keeps condensate out of the circuit unattended, the regulator holds a steady supply pressure and the lubricator mists oil to the actuation side.

build

Maintenance shop air-tool stations

A dedicated drop at a maintenance bench where impact wrenches, grinders and other air tools run all shift: the combination filters the shop air, regulates it to the pressure the tools were set up for, and delivers oil mist so the tools keep their internal lubrication.

conveyor_belt

Packaging and bottling line cylinder actuation

Supplying the air cylinders that drive diverters, pushers and sealing heads on a packaging line: clean, regulated and lubricated air keeps the stroke behaviour consistent through the shift, with the automatic drain handling condensate in humid plant conditions.

Is the GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port the Right Station?

Start with the port step: within the GC family the 200, 300, 400 and 600 sizes step up in port and capacity, so pick the size whose port (here G1, 1 in) matches the air main and leave headroom for the flow your line needs. Then set the drain: automatic drains itself, manual needs a routine walk-round, and differential-pressure is the default choice; this configuration uses automatic. Choose the filter grade - 40 um as standard protection, or 5 um (code W, as here) where finer particulate removal matters downstream. On the regulator, decide between the standard type and the low-pressure type (L), and pick the gauge style and scale: embedded square or external round, in MPa, psi or bar. Finally settle the thread - PT is the standard, with G (BSPP) and NPT as order options - and whether a bracket is included. Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port FAQ

For this series the flow data is published as curves rather than a single rated figure, so we do not quote one number here. Send us your application details - the air main size, the consumers on the line and their duty - and we will confirm the datasheet flow figures for the GC600 at G1 (1 in) on request before you order.

The L in the code selects the low-pressure variant of the regulator instead of the standard type, for circuits that run at lower supply pressures. The exact adjustment range for this variant is not published in the material we hold, so please confirm it with us on request. Everything else on the code decodes as: G1 (1 in) port with G thread, automatic drain, 5 um filter element, round psi gauge, reverse/check valve fitted, and bracket included.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025ALC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.