The AirTAC GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GC600 series unit is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator, each doing its own job in one assembled set. The filter element is the fine 5 um grade (the standard element is 40 um; W on the code selects 5 um) with an automatic drain, so collected water is expelled without manual attention. The bowl on the filter section is aluminium alloy, as is standard for the 600 size. The regulator is the low-pressure type and carries a round pressure gauge reading in psi; a reverse/check valve is also fitted. The set is supplied with a mounting bracket and takes a G1 (1 in) port with G thread. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC family is offered across the 200, 300, 400 and 600 sizes with a choice of ports, drain types, filter grades, gauges and thread options, so a configuration can be matched to the line it feeds. Flow figures for this series are published as curves rather than a single rated number; ask us and we will confirm the datasheet figures for your application on request.
| Model | GC60025ALC2WGK AirTAC F.R.L. Combination, G1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Feeding a cell of pick-and-place grippers and clamps: the 5 um element protects the directional valves from fine particulate, the automatic drain keeps condensate out of the circuit unattended, the regulator holds a steady supply pressure and the lubricator mists oil to the actuation side.
A dedicated drop at a maintenance bench where impact wrenches, grinders and other air tools run all shift: the combination filters the shop air, regulates it to the pressure the tools were set up for, and delivers oil mist so the tools keep their internal lubrication.
Supplying the air cylinders that drive diverters, pushers and sealing heads on a packaging line: clean, regulated and lubricated air keeps the stroke behaviour consistent through the shift, with the automatic drain handling condensate in humid plant conditions.
Start with the port step: within the GC family the 200, 300, 400 and 600 sizes step up in port and capacity, so pick the size whose port (here G1, 1 in) matches the air main and leave headroom for the flow your line needs. Then set the drain: automatic drains itself, manual needs a routine walk-round, and differential-pressure is the default choice; this configuration uses automatic. Choose the filter grade - 40 um as standard protection, or 5 um (code W, as here) where finer particulate removal matters downstream. On the regulator, decide between the standard type and the low-pressure type (L), and pick the gauge style and scale: embedded square or external round, in MPa, psi or bar. Finally settle the thread - PT is the standard, with G (BSPP) and NPT as order options - and whether a bracket is included. Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
For this series the flow data is published as curves rather than a single rated figure, so we do not quote one number here. Send us your application details - the air main size, the consumers on the line and their duty - and we will confirm the datasheet flow figures for the GC600 at G1 (1 in) on request before you order.
The L in the code selects the low-pressure variant of the regulator instead of the standard type, for circuits that run at lower supply pressures. The exact adjustment range for this variant is not published in the material we hold, so please confirm it with us on request. Everything else on the code decodes as: G1 (1 in) port with G thread, automatic drain, 5 um filter element, round psi gauge, reverse/check valve fitted, and bracket included.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.