The AirTAC GC60025ALF2WGK AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC60025ALF2WGK is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC600 unit. This configuration is built around a G1 (1 in) port, so it suits the supply side of a compressed-air system where the main line feeds multiple downstream circuits. The filter stage carries the 5 um element (code W) for finer water and particulate removal than the 40 um standard, with an automatic drain that expels collected condensate without manual attention. The regulator is the low-pressure type, fitted with an embedded square gauge reading in psi, and a reverse/check valve is fitted. The 600-size bowl is aluminium alloy and a mounting bracket is included.
This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, and options including drain type, filter grade, gauge style and scale, PT/G/NPT thread and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GC60025ALF2WGK AirTAC F.R.L. Combination, G1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Installed at the take-off from a compressor receiver into a 1 in distribution header, the GC60025ALF2WGK cleans, regulates and lubricates the air feeding an entire production hall's circuits. The automatic drain handles condensate at the filter bowl without daily operator rounds.
Mounted on the supply drop ahead of a bottling or cartoning conveyor line, this F.R.L. set protects cylinders, actuators and air bearings on the line: 5 um filtration for the finer contaminants, regulated low-pressure supply, and oil mist for moving seals and valves.
Fitted at the wall drop feeding a workshop's impact wrenches, riveters and air chisels, the combination keeps tool air clean, lubricated and held at a set pressure. The reverse/check valve holds the downstream circuit if supply dips, and the psi gauge gives operators a direct read.
Step up or down through the GC sizes (200/300/400/600) to match the port and the flow your line needs - the 600 size with a 1 in port sits at the top of the range for larger supply mains. Choose the drain type for the filter bowl: automatic (as here) for unattended condensate removal, manual where you prefer operator-controlled draining, or the differential-pressure default. Pick the 5 um element (W) when downstream equipment needs finer filtration than the 40 um standard. The gauge is the embedded square type; external round gauges and MPa/psi/bar scales are the decodable alternatives. Thread is G here, with PT as the standard and G/NPT as order options, and a bracket is included for mounting.
One honest note on sizing: AirTAC publishes flow as curves, not a single rated number, so we cannot quote a rated flow for this unit. Send us your application details and we will confirm the datasheet figures before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow number for this unit. Tell us your application and line conditions and we will confirm the datasheet flow curves for the GC600 size on request before you order.
The W in the model code specifies the 5 um element, one grade finer than the 40 um standard element, for tighter water and particulate removal ahead of sensitive equipment. The A specifies an automatic drain, which expels collected condensate from the bowl on its own instead of relying on the differential-pressure default or manual draining - useful where the unit is mounted in an unattended position.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.