The AirTAC GC60025C2K AirTAC F.R.L. Combination, PT1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC60025C2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled into one supply package. This size 600 unit is ported PT1 (1 in) with PT thread as standard, carries the standard 40 um filter element with a differential-pressure drain, and has aluminium alloy bowls, which is the bowl material used at size 600. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), a round gauge scaled in psi is fitted, a reverse/check valve is included, and the set comes with a mounting bracket.
This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options include a 5 um filter element (code W), automatic or manual drains, gauge scales in MPa, psi or bar, and G (BSPP) or NPT threads as order options. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application.
| Model | GC60025C2K AirTAC F.R.L. Combination, PT1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Filtered, regulated and lubricated air at the paint-line drop keeps spray guns and air-driven agitators supplied with clean, pressure-controlled, oil-misted air from a single assembly.
A three-unit F.R.L. at the header feeding pneumatic cylinders and clamps on a carton-forming conveyor gives one point to set line pressure, drain accumulated water and mist-lubricate the actuators.
At the drop from a plant air ring main to CNC fixture-clamping and workholding circuits, the combination protects the tools, holds the set pressure and lubricates the cylinders.
Sizing starts at the size and port step: size 600 with a PT1 (1 in) port is the largest step in the GC range, so match it against the air demand of the circuit rather than assuming the biggest size is always right. For this model the decodable choices are already fixed: 40 um filtration (5 um is the W option), differential-pressure drain, standard regulator with a 0.15-0.9 MPa (20-130 psi) range, and a round gauge scaled in psi. If you need finer filtration, a different drain type, another gauge scale, or G (BSPP) or NPT threads instead of PT, those are catalogue options to order. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC range as curves rather than a single rated figure, so there is no one number we can quote honestly. Tell us your line pressure and air demand and we will confirm the flow figures from the datasheet on request before you commit to a size.
A blank drain position on the GC code means the differential-pressure drain, which is what the GC60025C2K carries: it clears the filter bowl automatically as the pressure differential builds. Automatic (code A) and manual (code M) drains are catalogue options if you would rather control drainage differently.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.