The AirTAC GC60025F2GK AirTAC F.R.L. Combination Unit, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC60025F2GK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-treatment set. It removes water and particulate down to 40 um, regulates downstream pressure within a 0.15-0.9 MPa (20-130 psi) range, and adds oil-mist lubrication for downstream air tools and actuators. This 600-size unit is fitted with a G1 (1 in) port, a differential-pressure drain on the filter bowl, an embedded square gauge with a psi scale, a reverse/check valve, and a mounting bracket. The bowls on this size are aluminium alloy, and maximum inlet pressure is 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with a range of port sizes, drain types, filter grades (40 um standard, 5 um optional), gauge scales, thread options and check-valve choices. Rated flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GC60025F2GK AirTAC F.R.L. Combination Unit, G1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Installed at the drop from a large plant air ring main, the set cleans, regulates and lubricates the supply feeding presses and clamps across a heavy fabrication cell.
Feeding the cylinder banks that drive conveyor stops, pushers and gating on a bottling line, where clean, regulated and lubricated air keeps motion consistent through long shifts.
Supplying impact wrenches and nutrunners at vehicle assembly torque stations, where the lubricator carries oil mist to the tools and the regulator holds steady setting pressure.
Sizing starts with the port and size step: this unit is a 600-size with a G1 (1 in) port, the largest step in the GC range, so match it against the flow your line needs before ordering. The filter is set to the 40 um standard grade (a 5 um element is available as code W on other variants), and the drain here is differential-pressure, which discharges collected condensate on the pressure differential; automatic (A) and manual (M) drains are available on other variants. The gauge is the embedded square type with a psi scale (MPa and bar scales exist), the regulator is the standard type, and the K code means a reverse/check valve is fitted. The trailing G denotes G (BSPP) thread; PT is the standard thread and G/NPT are catalogue options to order, and a mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the flow your application needs, and we will confirm the sizing from the datasheet on request.
K means a reverse/check valve is fitted, holding downstream pressure if the upstream supply drops. The drain on this unit is the differential-pressure type, which discharges condensate from the filter bowl automatically on a pressure differential; automatic (A) and manual (M) drain variants exist elsewhere in the series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.