The AirTAC GC60025LC2G AirTAC F.R.L. Combination, G1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This GC60025LC2G is the size 600 unit with a G1 (1 in) G-thread port, the standard 40 um filter element and a differential-pressure drain on the filter bowl. The regulator is the low-pressure type, a round gauge with a psi scale is fitted, and the bowls on this size are aluminium alloy. Maximum inlet pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C (non-freezing). A mounting bracket is included and no reverse/check valve is fitted.
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, plus drain, filter-grade (40 um standard, 5 um with the W code), gauge-scale and thread (PT standard, G and NPT orderable) options. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet numbers for your application before ordering.
| Model | GC60025LC2G AirTAC F.R.L. Combination, G1 (1 in) Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Conditioning the main air supply to a paint shop: water and particulate removed ahead of the regulator, oil mist added for spray-gun and air-tool lubrication, with pressure set to suit the low-pressure requirements of the line.
Feeding filtered, regulated and lubricated air to the cylinders and grippers on a bottling or canning conveyor, with the 1 in G-thread port serving the line's main drop from a single preparation set.
Air preparation for large pneumatic presses and clamping fixtures, where one three-unit F.R.L. set conditions the whole machine supply taken from a 1 in main.
Size and port come first: the 600 body steps up to a 1 in port, so match the series to the main air line serving the machine rather than to individual drops. Where a bowl is present you choose the drain: differential-pressure (standard, as on this model), automatic (A) or manual (M). Filter grade is 40 um standard or 5 um with the W code if finer particulate capture is needed. The gauge on this unit is round with a psi scale; the embedded square gauge and MPa or bar scales are the other catalogue options. Thread is G (BSPP) here, with PT as the standard and NPT orderable. This is the low-pressure regulator type; its exact adjustment range is not published, so confirm it with us.
Because AirTAC publishes flow for this series only as curves, not a single rated number, send us your application's air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your application's air demand and we will confirm the sizing from the datasheet on request.
The L code in GC60025LC2G selects the low-pressure regulator type instead of the standard one. The exact adjustment range for this configuration is not published in our data, so confirm the range with us before ordering if your line runs at low pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.