The AirTAC GC60025MC2K AirTAC F.R.L. Combination, PT1 in, psi Gauge is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC60025MC2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. It conditions compressed air in a single station - removing water and particulate down to 40 um, holding downstream pressure anywhere in the 0.05-0.9 MPa (7-130 psi) adjustment range, and adding oil mist for downstream air tools and cylinders. This size-600 unit is specified with a PT1 (1 in) port, manual drain, a fitted round gauge scaled in psi, and a reverse/check valve (code K). The 600-size bowls are aluminium alloy. Maximum working (inlet) pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with port options from PT1/8 up to PT1, a choice of drain type (differential-pressure, automatic or manual), a 5 um filter element option (code W), gauge style and scale choices, and G or NPT thread variants as order options. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.
| Model | GC60025MC2K AirTAC F.R.L. Combination, PT1 in, psi Gauge |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Drops off a 1 in compressed-air ring main feeding assembly stations: the filter clears water and swarf, the regulator holds a steady tool pressure, and the lubricator feeds the impact wrenches and nutrunners on the line.
Conditions the air feeding conveyor gate cylinders and reject pushers on a bottling or canning line, where the manual drain lets maintenance purge accumulated condensate at each shift check and the psi gauge gives operators a visible setpoint.
A central conditioning point for a fabrication bay running grinders, chippers and pneumatic clamps from a large-bore supply: the check valve holds the set pressure against upstream fluctuation and the lubricator keeps air tools running smoothly.
Start with the size and port: 600 is the largest G-series step, and this unit carries PT1 (1 in) ports - match it to your line diameter and the flow your application needs. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. The drain here is manual, so an operator opens the drain periodically; if you would rather not rely on that, differential-pressure and automatic drain variants exist in the family. The filter element is the standard 40 um grade; the 5 um element (code W) is available if finer filtration is required. The fitted round gauge reads in psi; embedded square gauges and MPa/bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included with this unit.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number here. Tell us your application and we will confirm the flow and sizing from the datasheet on request before you order.
The M in the code specifies a manual drain: an operator opens it periodically to expel collected condensate. If you prefer unattended operation, the GC family also offers a differential-pressure drain (the default) and an automatic drain (code A) - we can quote the equivalent variant on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.