The AirTAC GC60025MF2WG AirTAC F.R.L. Combination, G1 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC60025MF2WG is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC600 unit for compressed-air preparation. This configuration is built around a G1 (1 in) port with G (BSPP) thread, a 5 um filter element (the finer of the two published grades), a manual drain on the filter bowl, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). The square pressure gauge is fitted and reads in psi, the filter bowl on this 600 size is aluminium alloy, and the unit ships with its mounting bracket. No reverse/check valve is fitted in this code.
This is a genuine AirTAC part from the G-series range, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, and options for thread type (PT standard, G or NPT to order), drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um) and gauge scale (MPa, psi or bar). Max working inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC60025MF2WG AirTAC F.R.L. Combination, G1 Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Feeds paint-booth air drops on an automotive assembly line, where the 5 um element, regulated pressure and oil misting protect spray guns and keep finish quality consistent.
Supplies filtered, regulated and lubricated air to the pneumatic clamps and tool-change actuators of a CNC machining cell running on a 1 in plant-air main.
Prepares air for the grippers, diverters and stopper cylinders on a bottling or packaging conveyor line, with the manual drain emptied during scheduled changeovers.
The GC600 size step is the right choice when your line needs the largest published port, G1 (1 in), and the flow capacity that goes with it; smaller demands can step down to GC200, GC300 or GC400 with 1/8 in to 3/4 in ports. The 5 um element (code W) suits air that feeds sensitive valves, cylinders or instruments; the 40 um standard grade is enough for general plant air. Manual drain means an operator opens the drain at intervals - choose automatic or differential-pressure drain codes if nobody will be at the unit regularly. The fitted square gauge here reads in psi; MPa or bar scales and an external round gauge are available. PT is the standard thread; G and NPT are order options. Bracket is included on this code. Flow is published as curves, not a single rating, so send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and line pressure and we will confirm the datasheet flow figures for this G1 (1 in) unit on request before you order.
The M in GC60025MF2WG specifies a manual drain on the filter bowl: an operator opens it at intervals to remove collected water. If no one will attend the unit regularly, order a GC600 code with A (automatic drain) or leave the position blank for the differential-pressure drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.