The AirTAC GC60025MLF2W AirTAC F.R.L. Unit, PT1 in. (GC600) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC60025MLF2W is a three-piece AirTAC GC-series F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-treatment stack. It filters compressed air (water and particulate, with the 5 um W-grade element fitted), regulates downstream pressure with the low-pressure type regulator, and adds oil-mist lubrication for downstream tools and actuators. This configuration is the size 600 frame with a 1 in. PT port, a manual drain on the filter bowl, a 5 um filter grade, and the embedded square gauge on a psi scale. The filter bowl on this size is aluminium alloy, and the unit includes a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in. to 1 in., and can be ordered with G (BSPP) or NPT threads as catalogue options, automatic or differential-pressure drains, 40 um or 5 um filtration, MPa/psi/bar gauge scales, and a reverse/check valve. Flow for this series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC60025MLF2W AirTAC F.R.L. Unit, PT1 in. (GC600) |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT1" · 5 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-25 |
| Build order | Filter → regulator → lubricator |
Installed at the header feeding a packaging hall's 1 in. distribution line: the filter strips water and fine particulate, the low-pressure regulator holds a set downstream pressure, and the lubricator carries oil mist out to the palletisers, case sealers and strapping heads on the line.
Mounted ahead of the valve manifold that drives conveyor stops, gating cylinders and pusher actuators on a bottling line, giving those air cylinders clean, regulated, lubricated air from a single 1 in. supply drop, with the psi gauge giving operators a visible setpoint.
Fitted on the air service drop serving a machining cell's clamping fixtures and pneumatic tool circuits, where the 5 um element protects the clamps from fine contamination and the lubricator keeps air tools running smoothly through the shift.
Start with the port and size: this unit is the size 600 frame with a 1 in. PT port, the largest step in the GC range, so size up to it when your line flow demands the biggest porting and size down (300/400) when it does not. Because flow is published as curves and not a single rated number, send us your flow requirement and we will confirm the right size from the datasheet before you order. On treatment choices: this unit carries the 5 um W-grade element instead of the standard 40 um, which suits finer particulate control; the drain is manual, so an operator drains the bowl rather than relying on an automatic or differential-pressure drain; and the gauge is the embedded square type on a psi scale (MPa and bar scales and an external round gauge are order options). The regulator here is the low-pressure type; its exact adjustment range is not published in the material we hold, so confirm it with us. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your line pressure and required flow and we will confirm the sizing against the datasheet curves on request before you order.
The M in this model code specifies a manual drain, meaning the condensate in the filter bowl is drained by hand as part of routine checks. The GC series is also catalogued with automatic and differential-pressure drains, so if you would rather not rely on manual draining, ask us for the equivalent GC600 configuration with the drain type you prefer.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.