verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure

The AirTAC GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$198.90 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure

The AirTAC GC60025MLF2WGK is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator that together clean, regulate and lubricate compressed air on one supply line. This size 600 configuration is built around a G1 (1 in) port with G (BSPP) thread, and the code fixes every working detail: a 5 um filter element (the finer of the two published grades) with a manual drain on the filter bowl, a low-pressure type regulator, an embedded square gauge reading in psi, a reverse/check valve fitted on the regulator, and aluminium alloy bowls - the material used at size 600. The medium is compressed air only, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, so the same three-unit concept is available from 1/8 in up to 1 in ports, with a choice of drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um with code W), gauge style and scale (MPa, psi or bar), thread (PT standard, G and NPT as order options) and bracket. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and flow curves for this exact model on request before you order.

GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure Technical Specifications

ModelGC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 5 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure Is Used

factory

Automotive paint shop air drops

Feeds spray-booth and paint-gun air drops on a 1 in main: the 5 um element takes water and particulate out ahead of the guns, the regulator holds a steady low pressure for finish consistency, and the lubricator mists oil into the air line for gun and tool life.

conveyor_belt

Bottling and packaging line supply

Sits at the head of a packaging line's 1 in air main, conditioning the air feeding cylinder-actuated case packers, sealers and labelers - filtered, regulated and lubricated air in one pass, with the check valve holding the set pressure against supply dips.

engineering

Machine-shop pneumatic clamping

Conditions the air feeding pneumatic clamps and workholding fixtures on CNC cells: clean, dry air protects the fixtures, the low-pressure regulator suits sensitive clamping pressures, and the psi gauge gives operators a direct read at the cell.

Is the GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure the Right Station?

Size and port are the first decision: 600 is the largest step in the GC range, and here it carries a G1 (1 in) port with G (BSPP) thread - step down to 200/300/400 if your line is smaller, but match the port to the pipe and the air demand of the machines downstream. Filter grade is already fixed at 5 um (code W); if your application tolerates coarser air, the 40 um standard element is the alternative grade in this family. Drain is manual on this unit, so an operator drains the bowl on a schedule - choose automatic or differential-pressure drain codes if the installation is unattended. The regulator is the low-pressure type; its exact adjustment range is not published, so confirm it against your working pressure with us before ordering. The fitted square gauge reads psi; MPa and bar scales and an external round gauge are the other published options. PT is the standard thread, with G and NPT available to order, and a mounting bracket is included. Flow for this family is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure FAQ

AirTAC publishes flow for the GC family as curves, not as a single rated figure, so there is no one rated flow number we can state for this unit. Tell us your line pressure and the air demand of the equipment downstream, and we will confirm the flow curves and datasheet for this exact model on request before you order.

The M in the code GC60025MLF2WGK specifies a manual drain on the filter bowl - an operator opens it to discharge collected water and dirt on a schedule. The GC family also offers automatic drain (code A) and differential-pressure drain (blank, the default), so if the installation runs unattended, ask us for the equivalent model with one of those drain codes.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC60025MLF2WGK AirTAC F.R.L. Unit G1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025MLF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.