The AirTAC GFR200-06MC1TK AirTAC Filter Regulator 1/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06MC1TK is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration has a 1/8 in NPT port, a manual drain bowl in PC (polycarbonate), a 40 um standard filter element, a round pressure gauge scaled in MPa, a reverse/check valve fitted, and a mounting bracket included. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi) for manual-drain versions, and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the GFR filter-regulator line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, an optional 5 um element (code W), square or round gauges with MPa, psi or bar scales, G (BSPP) or NPT thread options, and bracket choices. We confirm flow and datasheet figures on request - just ask before ordering.
| Model | GFR200-06MC1TK AirTAC Filter Regulator 1/8 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Conditioning and pressure regulation for the small pneumatic cylinders that drive sealing, folding and eject stations on a packaging line, with the manual drain emptied during shift checks.
A clean, set-and-held supply point for bench-top air tools and test rigs, where the 40 um element keeps particulate out of sensitive fittings and the MPa gauge gives a clear set-point readout.
Filtering and regulating air at an individual workstation or clamp fixture, with the reverse/check valve holding the downstream setting if the main supply dips and the bracket securing the unit to the frame.
Size and port: the 200 frame with a 1/8 in port is the compact end of the GFR range; step up to 300, 400 or 600 when your line needs larger ports and more flow. Drain: this unit is manual drain, which also widens the regulation range to 0.05-0.9 MPa (7-130 psi); automatic or differential-pressure drain versions regulate 0.15-0.9 MPa (20-130 psi). Filter grade: 40 um is standard here; specify the W code for a 5 um element where finer filtration is needed. Gauge: the round gauge on this unit reads in MPa, and square embedded gauges or psi/bar scales are alternatives. Thread: PT is the standard; G (BSPP) and NPT are catalogue options, and this unit is ordered in NPT. Bracket: included on this code (J deletes it).
One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a flow number. Send us your application and we will confirm sizing against the datasheet curves before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote a flow number here. Tell us your application and required flow, and we will confirm sizing against the datasheet curves on request before you order.
The M in the code specifies a manual drain: condensate is emptied by hand from the PC bowl rather than automatically. The catalogue also ties the regulator range to drain type - manual-drain units adjust from 0.05-0.9 MPa (7-130 psi), while automatic and differential-pressure drain versions adjust from 0.15-0.9 MPa (20-130 psi). If you would rather not drain by hand, ask about the automatic-drain variant of the same size.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.