The AirTAC GFR200-06T AirTAC Filter Regulator NPT 1/8 in, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06T (model code GFR20006MJNWTK) is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has 1/8 in NPT ports, a 5 um filter element, a manual drain and a built-in reverse (check) valve, and is supplied without a gauge or mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the set pressure is adjustable from 0.05 to 0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl shows the condensate level at a glance, and the manual drain is opened by hand to discharge it.
This is a genuine AirTAC part from the GFR series, which spans four sizes (200, 300, 400 and 600) with progressively larger ports and flow capacity. Across the series you can order differential-pressure, automatic or manual drains, a 40 um standard or 5 um fine element, an embedded square gauge or an external round gauge in MPa, psi or bar scales, PT, G or NPT threads, and a mounting bracket. Because AirTAC publishes flow only as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.
| Model | GFR200-06T AirTAC Filter Regulator NPT 1/8 in, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
A small air cylinder press at an assembly bench takes filtered, regulated air: the 5 um element keeps pipe scale and rust out of the regulator valve seat and cylinder seals, the built-in check valve holds the downstream circuit if supply dips, and the regulator sets the working pressure for the forming stroke.
On a carton-sealing or wrapping line, this unit conditions the air feeding gripper and clamp cylinders: water and particles down to 5 um are stripped out, pressure is held steady at the set point, and the manual drain is bled at shift start to clear overnight condensate.
A bench test rig running pneumatic experiments draws its supply through this unit: the fine 5 um element protects sensitive instrumentation and orifices, the regulator gives a repeatable set pressure between runs, and the PC bowl shows at a glance when the manual drain needs opening.
Choose the size step by the air demand of your line: 200 is the smallest GFR frame and carries a 1/8 in port here, while 300, 400 and 600 step up in port and capacity - ask us to confirm the flow curve against your requirement before ordering. Drain type matters: this unit has a manual drain you open by hand, whereas automatic and differential-pressure drains discharge condensate without attention. Filtration is 5 um on this code; the series standard is 40 um, with W marking the fine element. Gauges are optional across the series - embedded square or external round, in MPa, psi or bar scales - and none is fitted here. The thread is NPT on this unit; PT is the catalogue standard and G is also available. A mounting bracket is optional and not included on this configuration.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so no flow number is quoted here. Tell us your working pressure and air demand and we will confirm the flow curve and the datasheet figures for this exact configuration on request.
The manual drain on this unit is opened by hand to discharge collected condensate, which suits installations that are checked as part of a daily routine. The GFR series also offers automatic and differential-pressure drains that discharge without attention; choose one of those for unattended or hard-to-reach installations.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.