The AirTAC GFR200-06T AirTAC Filter Regulator, NPT1/8, 5 um, psi Gauge is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200-06T is a size-200 filter regulator that removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration has a 1/8 in NPT port, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element is high enough, and an embedded square gauge reading in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um or 5 um elements, differential-pressure, automatic or manual drains, psi/MPa/bar gauge scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR200-06T AirTAC Filter Regulator, NPT1/8, 5 um, psi Gauge |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use conditioning on a CNC machining centre: the 5 um element protects the machine's pneumatic solenoid valves from water and fine swarf-laden condensate, while the regulator sets a stable supply pressure for tool-change and clamping circuits.
Mounted at the feed end of a carton-sealing or case-packing conveyor, the unit filters the shop air feeding cylinder-driven pushers and sets the working pressure for consistent box handling, with the differential-pressure drain keeping the bowl clear unattended.
On a pilot-scale or laboratory skid running pneumatic valves and small actuators, the compact 1/8 in port and fine 5 um filtration keep instrument air clean and regulated, with the psi gauge giving operators a local pressure readout.
Size and port set the capacity: the 200 frame with a 1/8 in NPT port suits compact point-of-use drops; step up to 300/400/600 where the circuit demands more flow. The 5 um element in this unit is the right pick when downstream valves or instruments are sensitive to fine particulate; the 40 um grade is the standard choice elsewhere. The differential-pressure drain needs no operator attention, while automatic and manual drains are available as catalogue options. The fitted square gauge reads in psi; MPa and bar scales are also offered. PT is the standard thread, with G and NPT as orderable options, and a mounting bracket is included. Because flow is published as curves rather than one rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and the flow your circuit needs, and we will confirm the correct size from the datasheet on request before you order.
This unit carries the 5 um element (code W), the finer of the two catalogue grades. Choose it when downstream solenoid valves, air bearings or instruments need protection from fine particulate; the 40 um grade is the standard choice for general cylinder circuits. Both grades are available across the GFR range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.