GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge

The AirTAC GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$46.89 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge

The AirTAC GFR200-08 is a size-200 filter regulator that removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration has a 1/4 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate whenever the pressure drop across the element rises, a round pressure gauge scaled in psi, a built-in reverse (check) valve, and a mounting bracket. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter elements, and gauge scale options. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request.

GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge Technical Specifications

ModelGFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge
SeriesGFR200 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge

GFR200G-series filter regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/4" · 40 µm
One size upGFR300
Add lubricationGFC200-08 (two-unit set)

Where the GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge Is Used

precision_manufacturing

CNC machine tool air supply

Conditioning the shop-air feed to a CNC machining centre's pneumatic tool-changer and clamping circuits: the 40 um element strips water and swarf carried in the ring main, and the psi gauge lets maintenance set and verify the clamp pressure at the machine.

science

Laboratory air line for analytical instruments

Feeding clean, regulated air to lab analysers or sample-prep stations: the filter section removes moisture and particulate ahead of sensitive pneumatics, the regulator holds a steady setpoint, and the check valve prevents backflow into the supply line.

conveyor_belt

Packaging line conveyor actuators

Supplying filtered, regulated air to the cylinders and air bells on a packaging or bottling conveyor: the differential-pressure drain keeps condensate out of the actuators between maintenance rounds, and the bracket gives a clean panel mount next to the line.

Is the GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge the Right Unit?

Start with the port step: size 200 with a 1/4 in NPT port suits lighter-duty circuits, while sizes 300, 400 and 600 carry progressively larger ports and higher flow capacity. Choose the drain to match maintenance access: differential-pressure (as fitted here) needs no timer, automatic drains continuously, and manual drain suits attended installations. Filter grade is 40 um as standard; specify W for the 5 um element where downstream equipment needs finer filtration. Gauge scale is selectable (MPa, psi or bar) - this unit carries a round psi gauge. Thread is PT as standard with G and NPT as order options; a bracket is included, or specify J to omit it.

Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated number, so we do not quote a flow figure here. Tell us your application and we will confirm the relevant datasheet curve and check the sizing for you before you order.

The differential-pressure drain fitted to this unit discharges collected condensate automatically when the pressure drop across the 40 um element rises - no timer or operator action needed. If you prefer continuous draining regardless of load, choose the automatic drain (code A); if the unit sits where an operator can bleed it routinely, the manual drain (code M) is the simpler choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200-08 AirTAC Filter Regulator, NPT1/4, psi Gauge

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20008C2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.