The AirTAC GFR20006JF1T AirTAC Filter Regulator NPT 1/8 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006JF1T is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This unit is the 200 size with a 1/8 in NPT port, 40 um standard filtration, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and an embedded square pressure gauge scaled in MPa. The standard regulator covers a 0.15-0.9 MPa (20-130 psi) adjustment range, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl keeps the media visible, and this code is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and is ordered with choices of drain type (differential-pressure, automatic or manual), filtration grade (40 um standard, 5 um with code W), gauge style and scale, thread (PT standard, G or NPT to order), bracket and reverse/check valve. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.
| Model | GFR20006JF1T AirTAC Filter Regulator NPT 1/8 in |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds a small clamping cylinder on a machining fixture: the 40 um element keeps swarf and pipe scale out of the cylinder seals while the regulator holds a fixed clamp pressure, with the MPa gauge giving the setter a direct reading at the station.
Conditions the air feeding a blow-off nozzle on a carton-sealing conveyor: water and 40 um particulate are stripped out before the nozzle, and the regulator lets the line operator set a stable, repeatable blow pressure for consistent label and dust removal.
Serves as the compact conditioning point on a laboratory or QC test bench: the 1/8 in NPT port suits small-diameter rig tubing, the differential-pressure drain keeps condensate from accumulating during long runs, and the gauge supports repeatable test-point pressures.
Start with the port step: this code is the 200 size at 1/8 in NPT, the smallest GFR port, so step up to GFR300/400/600 if your line needs more flow capacity. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order. Then pick the decodable options: drain type (differential-pressure as here, automatic, or manual - note the manual-drain version widens the regulation range down to 0.05 MPa), filtration grade (40 um standard, 5 um with code W for finer protection), gauge scale (MPa as here, psi or bar), thread (PT is the standard, G and NPT are catalogue options), and bracket (this code ships without one; a bracket can be ordered).
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves in the catalogue, not as a single rated number, so we do not quote a l/min or SCFM figure for this unit. Send us your application - port size, downstream demand and working pressure - and we will confirm the flow and full datasheet figures for the GFR200 at 1/8 in NPT on request before you order.
The blank drain position on this code is the differential-pressure type: condensate in the polycarbonate bowl is discharged automatically as air flows through, with no operator action. The catalogue alternatives are the automatic drain (code A) and the manual drain (code M); note that the manual-drain version also widens the regulator adjustment range down to 0.05 MPa (7 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.