The AirTAC GFR20006LJC2TK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006LJC2TK is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This 200-size unit is fitted with 1/8 in NPT ports, the low-pressure regulator type, a 40 um standard filter element and the differential-pressure drain, the standard drain option for this family. The polycarbonate bowl suits the -5 to 70 C (non-freezing) operating range, a round gauge with a psi scale is included so the set pressure can be read directly, and a reverse (check) valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi). No mounting bracket is included on this code.
This is a genuine AirTAC part. The GFR family is published in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in and thread options PT, G (BSPP) and NPT, with 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, and square or round gauges in MPa, psi or bar scales. Flow for this model is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR20006LJC2TK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Filtering and regulating the air feeding pneumatic grippers on an electronics assembly cell, where the low-pressure type is chosen for circuits that run below the standard regulator range and delicate parts need gentle handling.
Conditioning compressed air for laboratory analysers and test benches that need moisture and particulate removed and the supply pressure set at a low, stable value, with the psi gauge letting the operator verify the setting.
Supplying filtered, regulated air to a bank of directional control valves on a packaging machine, with the fitted round psi gauge and check valve protecting the set pressure in the circuit.
The real, decodable choices on this code: the 200 size with 1/8 in NPT port is the smallest porting step in the GFR range, so step up to 300/400/600 when your line needs larger ports; the L marks the low-pressure regulator type, selected for circuits that run below the standard regulator range - the exact adjustment range for the low-pressure version is not published, so confirm it with us; the 40 um element is the standard grade, with 5 um (W) available when finer filtration is needed; the round gauge fitted here carries a psi scale, while the embedded square gauge with MPa/psi/bar scales is the alternative. This unit has no mounting bracket (J) and includes a reverse/check valve (K). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your application and we will confirm the flow data from the datasheet on request before you order.
The L in the code marks the low-pressure regulator type, selected for circuits that run below the standard regulator range. The exact adjustment range for the low-pressure version is not published, so ask us to confirm it against your set pressure. Everything else decodes normally: 1/8 in NPT ports, 40 um element, differential-pressure drain, round psi gauge and a fitted reverse/check valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.