verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um

The AirTAC GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$45.32 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um

The AirTAC GFR20006LJF2WK is a size-200 GFR series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a 5 um filter element (code W), a differential-pressure drain on the PC bowl, a low-pressure regulator type, an embedded square gauge reading in psi, and a reverse/check valve fitted. The port is PT1/8 (1/8 in) with PT thread as standard, and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, gauge scale options, and G or NPT thread variants to order. Because flow is published as curves rather than a single rating, we confirm the datasheet and sizing figures for your application on request.

GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um Technical Specifications

ModelGFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um
SeriesGFR200 filter regulator
Port sizePT1/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/8" · 5 µm
One size upGFR300
Add lubricationGFC200-06 (two-unit set)

Where the GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um Is Used

science

Pneumatic test and calibration benches

On a lab or pilot bench running low-pressure air circuits, this 1/8 in filter regulator cleans the supply with a 5 um element, holds a reduced set pressure read on the psi gauge, and the check valve holds the setting if supply dips.

precision_manufacturing

Small pick-and-place gripper circuits

Compact grippers and small actuator circuits on assembly cells take point-of-use air from this size-200 unit: filtered to 5 um, regulated to the low pressure the gripper needs, with the square psi gauge giving operators a visible setpoint.

tune

Low-pressure air jets on packaging lines

Blow-off and cleaning jets on packaging machinery often run below standard circuit pressure. This low-pressure type filter regulator at the jet drop lets the line set a gentle, stable pressure while the 5 um element keeps the nozzles clear.

Is the GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um the Right Unit?

Start with the port step: this unit is size 200 with a 1/8 in PT port, so match it to the line size and the air demand of the circuit; larger GFR sizes (300/400/600) carry larger ports for higher demand. The 5 um element here is the finer of the two published grades (40 um is standard), so choose it where downstream components need cleaner air. The differential-pressure drain bleeds accumulated condensate automatically as the pressure differential changes, with no manual draining routine. The square gauge is set to the psi scale; MPa and bar scales are alternatives in the series. PT thread is standard on this code, with G (BSPP) and NPT available as order options, and a mounting bracket can be added where this no-bracket code needs one. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and air demand and we will confirm the flow and sizing from the datasheet on request before you order.

K means a reverse (check) valve is fitted, so downstream pressure is held if the supply drops. The drain on this unit is the differential-pressure type: condensate collected in the PC bowl is discharged automatically as the pressure differential changes, with no manual draining needed. This code is also the low-pressure regulator type with a 5 um element and a square psi gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR20006LJF2WK AirTAC Filter Regulator PT1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20006LJF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.