The AirTAC GFR20006MJF2GK AirTAC Filter Regulator G1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200 is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in one compact body. This unit is the 200 size with a G1/8 port, manual drain, standard 40 um filter element, an embedded square gauge reading in psi, and a built-in check valve so downstream air does not back-feed through the regulator. The regulator adjusts from 0.05 to 0.9 MPa (7 to 130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the polycarbonate bowl suits -5 to 70 C non-freezing operation. This configuration is supplied without a mounting bracket.
This is a genuine AirTAC part from the GFR series, offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, and G or NPT thread options alongside the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application on request.
| Model | GFR20006MJF2GK AirTAC Filter Regulator G1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use filter regulation ahead of a directional-valve manifold on an assembly machine, keeping supply air dry and holding line pressure at the setpoint.
Filtered, regulated air for pick-and-place grippers on a bottling conveyor, with the check valve holding the downstream circuit if upstream supply drops.
A dedicated filter regulator at the air drop feeding a CNC machining cell, protecting solenoid valves and pneumatic clamps from water and scale in shop air.
Size the GFR by port and expected air demand: the 200 body takes a 1/8 in port, with the 300, 400 and 600 bodies stepping up to 1 in for larger circuits. Drain choices are differential-pressure (default), automatic (A) or manual (M, this unit) - manual suits installations where an operator can regularly bleed water from the bowl. Filter grade is 40 um standard; specify W for the 5 um element when finer protection is needed. The embedded square gauge is standard with MPa, psi or bar scales, and an external round gauge is optional. Thread is PT as standard with G (BSPP) and NPT as catalogue options; brackets are optional and this configuration omits one. Because flow is published as curves, not a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote one number. Send us your operating pressure and air demand and we will confirm the flow from the datasheet for this exact model on request.
The M in the code selects a manual drain: an operator opens the drain to bleed accumulated water from the bowl. If the unit cannot be serviced regularly, the GFR200 is also available with the differential-pressure drain (default) or the automatic drain (code A).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.