The AirTAC GFR20006MLC2WG AirTAC Filter Regulator G1/8 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006MLC2WG is an AirTAC GFR200 filter regulator: one body that removes water and particulate from compressed air and holds a regulated downstream pressure. This configuration has a G1/8 (1/8 in) port, the 5 um filter element (code W, the finer of the two published grades), a manual drain on the PC bowl, a round pressure gauge reading in psi, and the low-pressure regulator type; a mounting bracket is included. It is rated for a maximum inlet pressure of 1.0 MPa (145 psi) and for use from -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, drain choices of differential-pressure, automatic or manual, and 40 um or 5 um filtration. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR20006MLC2WG AirTAC Filter Regulator G1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds spray guns on a finishing line with air that has passed a 5 um element, while the low-pressure regulator holds the gun supply at the set pressure the operator dials in. The manual drain lets the booth operator clear the PC bowl at the start of each shift.
Conditions the supply to benchtop lab and analytical instruments that need particulate- and moisture-reduced air at a stable, modest pressure. The round psi gauge gives a direct local reading, and the bracket mounts the unit to the instrument frame.
Sits upstream of the small cylinders and grippers on a packaging-machine pick-and-place head, filtering the shop air and regulating it to the pressure the gripper circuit was set up with. The 1/8 in port suits the compact valve and tubing runs on these modules.
The real choices on this family are the size and port step (200 through 600, 1/8 in to 1 in) matched to the air demand of the circuit, the filter grade (40 um standard or 5 um with code W, as fitted here), the drain type (manual here; automatic and differential-pressure are alternatives), the gauge and its scale (MPa, psi or bar), the thread (PT standard, G or NPT to order) and the bracket. This unit is also the low-pressure regulator type, so its set-point range differs from the standard type - confirm it against your working pressure. Because flow is published as curves and not a single rated figure, ask us to check sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and datasheet figures for the GFR200 at the G1/8 port on request.
The W in the code selects the finer 5 um element instead of the 40 um standard, which suits points of use that see finer contamination. The M selects a manual drain, so the PC bowl is emptied by hand; automatic and differential-pressure drains are available on the family if you would rather not rely on an operator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.