The AirTAC GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$52.74 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa

The AirTAC GFR300 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is the 300 size with a 1/4 in NPT port, standard 40 um filtration, and a differential-pressure drain that automatically bleeds accumulated condensate whenever the pressure differential across the element is sufficient - no daily manual draining required. A round pressure gauge on the MPa scale is fitted, and a reverse/check valve is installed so downstream pressure is held if the upstream supply is lost.

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, and with manual or automatic drain, 5 um filtration (code W), square or round gauges on MPa, psi or bar scales, and G or NPT threads as order options. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.

GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa Technical Specifications

ModelGFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa
SeriesGFR300 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa Is Used

factory

Pneumatic press line drop regulation

Installed at the drop feeding a pneumatic press station, the GFR300-08 cleans the supply air of water and debris and holds a stable, reduced working pressure so the press cylinder cycles consistently regardless of header fluctuations.

conveyor_belt

Conveyor divert and stopper air prep

Mounted at the take-off for conveyor diverters, stoppers and gate cylinders, this unit filters condensate and particulate out of the 1/4 in branch line and regulates it to the pressure the actuators were designed for, with the check valve holding position if supply air is interrupted.

settings_input_component

Machine panel air supply point

Fitted inside a machine's air preparation panel, the unit provides one filtered, regulated supply point for the machine's valves and cylinders, with the MPa gauge giving the operator a direct reading of set pressure and the bracket allowing clean panel mounting.

Is the GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa the Right Unit?

Size and port: the 300 size with a 1/4 in NPT port suits lines where the required flow falls in the mid range of the G-series span; step up to 400 or 600 for larger ports and higher flow, or down to 200 for compact circuits. Drain type: this unit uses the differential-pressure drain (the default); choose automatic drain (code A) for unattended condensate removal or manual drain (code M) where you want controlled discharge. Filter grade: 40 um is standard for general air preparation; specify 5 um (code W) where downstream components need finer protection.

Gauge: a round gauge on the MPa scale is fitted here; square embedded gauges and psi or bar scales are alternatives. Thread: this unit is ordered with NPT; PT is the standard thread and G (BSPP) is also a catalogue option - all are specifications to order, not delivery statements. A reverse/check valve (code K) is fitted, and the mounting bracket is included. Regulation range is 0.15-0.9 MPa (20-130 psi) with this differential-pressure drain. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application's flow and pressure requirements and we will confirm the sizing from the datasheet curves on request before you order.

This unit's differential-pressure drain discharges accumulated condensate automatically whenever the pressure differential across the filter element is high enough - it is the default and needs no daily attention. If you prefer controlled discharge, order the manual drain (code M); for fully unattended condensate removal, the automatic drain (code A) is the alternative. All drain options keep the same 0.15-0.9 MPa (20-130 psi) regulation range except that the manual-drain version widens the lower end to 0.05 MPa (7 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300-08 AirTAC Filter Regulator NPT1/4 Round Gauge MPa

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008C1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.