The AirTAC GFR300-08AF2T AirTAC Filter Regulator 1/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-08AF2T is a size-300 filter regulator that removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1/4 in NPT port, a 40 um standard filter element, an automatic drain that ejects collected condensate without manual attention, and a fitted embedded square gauge reading in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing). The polycarbonate bowl includes a mounting bracket.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with manual, automatic or differential-pressure drains, 40 um or 5 um (W) filter grades, MPa, psi or bar gauge scales, and G, NPT or PT threads. Flow is published as curves rather than a single rated figure, so we confirm datasheet and flow figures on request.
| Model | GFR300-08AF2T AirTAC Filter Regulator 1/4 in NPT |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-08 (two-unit set) |
Clean, regulated air to a stamping or clamping fixture, with the automatic drain protecting the cylinder from accumulated condensate between cycles.
Point-of-use filtration and pressure control for carton sealers and wrapping equipment, with the psi square gauge giving operators a direct setpoint readout.
Regulated air for conveyor-mounted actuators and cleaning nozzles, with the 40 um element keeping particulate out of valves along the line.
Step up or down through the GFR sizes (200/300/400/600) to match the port and flow band your line needs; this size-300 unit carries a 1/4 in NPT port. Choose the drain to suit access: automatic (as here) where the unit is hard to reach, manual where you prefer controlled blowdown, or differential-pressure as the default. The 40 um element is standard; specify 5 um (code W) for finer protection. Gauge scale is selectable as MPa, psi or bar, and thread options are PT (standard), G (BSPP) or NPT.
Flow for this family is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so no single number is quoted here. Ask us and we will confirm the flow and datasheet figures for this 1/4 in NPT size-300 unit against your application before you order.
This unit carries code A, the automatic drain, which discharges collected condensate on its own. It suits installations where the bowl is awkward to reach or where staff cannot be relied on to drain it manually; manual (M) and differential-pressure (blank) drains are available in the same series if you prefer those.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.