The AirTAC GFR300-15AF2WTK AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-15AF2WTK is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This 300-size unit has a 1/2 in NPT port, a 5 um filter element for finer filtration than the standard 40 um grade, an automatic drain that expels collected condensate without manual attention, an embedded square gauge reading in psi, a reverse/check valve fitted, and a mounting bracket included. Max inlet pressure is 1.0 MPa (145 psi), the regulation range is 0.15-0.9 MPa (20-130 psi), and the operating temperature is -5 to 70 C (non-freezing). The polycarbonate bowl suits the 300 size; only the 600 size uses an aluminium alloy bowl.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, drain types (differential-pressure, automatic, manual), filter grades (40 um standard, 5 um optional), gauge styles and scales, and G/NPT thread options. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR300-15AF2WTK AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Feeds clean, regulated air to the cylinders and actuators on a packaging line, with the 5 um element and automatic drain keeping moisture and fine particles away from the mechanism between shifts.
Supplies filtered, pressure-controlled air to bench-mounted test rigs and lab equipment, where the 5 um grade and psi gauge give a clean, readable supply for repeatable work.
Regulates air to conveyor gates, diverters and stopper cylinders, with the check valve holding the set circuit against backflow and the automatic drain handling condensate along the line.
Size the unit by the port step: 200 (1/8-1/4 in), 300 (3/8-1/2 in), 400 (3/4 in) and 600 (1 in) cover increasing flow demand, so step up a size if your line sits near the top of a curve. Choose the drain to match the site: automatic (this unit) suits unattended installations, manual suits periodic checks, and the differential-pressure default drains on load change. Pick the filter grade for the task: 40 um standard for general protection, 5 um (code W, as here) for finer air ahead of sensitive components. Select the gauge scale (MPa, psi or bar) and thread (PT standard; G and NPT orderable), and add or omit the bracket as the mounting requires. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number. Tell us your application and we will confirm the relevant flow curve and datasheet figures on request before you order.
The A in the code selects the automatic drain, which expels collected condensate from the bowl without manual attention - useful where the unit is mounted in a hard-to-reach spot. The K adds a reverse/check valve, and the W selects the finer 5 um element instead of the 40 um standard.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.