The AirTAC GFR300-15ALC3T AirTAC Filter Regulator NPT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300-15ALC3T is an AirTAC GFR300 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the 300 size with a 1/2 in NPT port, automatic drain, standard 40 um filter element, low-pressure regulator type, and a round pressure gauge on the bar scale. The polycarbonate bowl suits this size, the mounting bracket is included, and the unit carries a maximum inlet pressure of 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, drain choices of differential-pressure, automatic or manual, a 5 um element option (code W), and gauge, thread and bracket options. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure on request.
| Model | GFR300-15ALC3T AirTAC Filter Regulator NPT1/2 Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Feeds filtered, regulated air to carton-forming and sealing cylinders on a packaging line, with the automatic drain keeping condensate out of the downstream valves.
Supplies a pick-and-place gripper circuit controlled below standard line pressure; the low-pressure regulator type is intended for such circuits - ask us to confirm the exact adjustment range.
Regulates air to diverter gates and stopper cylinders along a conveyor line, with the 40 um element protecting the directional valves from water and particulate.
Choose the size and port to match required flow and piping - here the 300 size steps up to a 1/2 in NPT port. Drain options are differential-pressure (default), automatic (this unit) and manual; the automatic drain removes collected condensate without manual attention. Filter grade is 40 um as standard, with 5 um available as code W. Gauge scales come in MPa, psi or bar - this unit carries a round gauge on the bar scale. Thread is PT as standard, with G and NPT as order options, and the mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes filter-regulator flow as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow curve and sizing from the datasheet on request.
The L in the code marks the low-pressure regulator type, intended for circuits controlled below standard line pressure. The exact adjustment range for the low-pressure type is not published in the catalogue sheet, so ask us to confirm it before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.