The AirTAC GFR300-15T AirTAC Filter Regulator NPT1/2 with Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-15T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit is specified for 1/2 in NPT ports, carries a 40 um filter element, and uses a manual drain, so the bowl is emptied by opening the drain valve as part of routine checks. It is set with an embedded square gauge scaled in MPa, includes a reverse/check valve, and comes with a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, PT as standard thread and G or NPT as order options, plus a choice of drain type, 40 um or 5 um filtration, and gauge scale. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GFR300-15T AirTAC Filter Regulator NPT1/2 with Gauge |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Fitted at a 1/2 in branch off the shop-air header, it cleans water and scale from the supply and holds a steady, gauge-set pressure to the tools and cylinders served by that drop.
On a packaging line's pneumatic control circuit, the 40 um element protects directional valves from debris while the regulator keeps actuator speed consistent as header pressure wanders.
At a workshop bench or maintenance bay, it gives technicians a locally adjusted, filtered supply for impact tools, blow-off and test rigs, with the check valve holding the setting if upstream supply dips.
Start with the port and size step: this unit is 300 size with 1/2 in NPT ports, and larger sizes carry larger ports and more flow, so match the step to the air demand of the line. The manual drain here suits installations where an operator can bleed the bowl periodically; automatic or differential-pressure drains are available if the unit will sit where it cannot be attended. Filtration is 40 um standard, with 5 um (code W) where finer protection is needed, and the fitted square gauge reads in MPa (psi and bar scales are options).
Thread is NPT on this code; PT is the catalogue standard and G is also orderable. A bracket is included for panel or wall fixing. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure, set pressure and air demand and we will confirm the correct size from the datasheet on request.
The M in the code specifies a manual drain: the bowl is emptied by opening its drain valve during routine checks. If the unit will be mounted where it cannot be attended, the same series is available with an automatic drain (code A) or the differential-pressure drain that is the default, and the regulator setting range differs by drain type: 0.05-0.9 MPa (7-130 psi) with manual drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.