verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um

The AirTAC GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$50.83 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um

The GFR30008ALJC3WT is an AirTAC GFR300 filter regulator: water and particulate filtration plus pressure regulation combined in one body, sized for a 1/4 in (NPT1/4) port. This configuration carries the 5 um filter element (the finer option against the 40 um standard), an automatic drain that expels collected condensate without manual attention, and a round pressure gauge reading in bar. The regulator is the low-pressure type, the polycarbonate bowl suits the 300 size, maximum inlet pressure is 1.0 MPa (145 psi), and the unit operates from -5 to 70 C in non-freezing conditions. No mounting bracket is included with this code.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600, with 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um Technical Specifications

ModelGFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um
SeriesGFR300 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um Is Used

precision_manufacturing

Packaging machine clamp circuits

Filtered, regulated low-pressure air feeding the clamping cylinders on a carton-sealing line. The 5 um element protects valve and cylinder seals from particulate, and the automatic drain keeps condensate out of the circuit without daily bowl checks.

conveyor_belt

Conveyor diverter actuators

Supplying sorting and diverter cylinders on a distribution conveyor. The low-pressure regulator type suits gentle actuation settings, and the round bar gauge lets line staff verify the set pressure at a glance during shift checks.

build

Paint booth air supply

Conditioning shop air ahead of spray equipment in a finishing booth. The 5 um grade reduces particulate in the air reaching the gun, the automatic drain handles moisture at an unattended wall point, and the NPT1/4 port matches standard booth pipework.

Is the GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um the Right Unit?

Choose the size by port and demand: this 300 unit is set up for a 1/4 in NPT port, and the larger 400 and 600 sizes step up in port and flow. Where water carry-over matters, the 5 um element in this code is the finer choice against the 40 um standard; the automatic drain suits points that are not checked daily, while manual and differential-pressure drains remain available in the family. Gauge scale (MPa, psi or bar) and thread (PT standard, G or NPT to order) are decodable choices, as is the bracket option - this code omits it. Because flow is published as curves rather than one rated number, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um FAQ

AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure, port size and air demand, and we will confirm the applicable curve and sizing from the datasheet on request.

It specifies an NPT thread: this unit has a 1/4 in NPT port. PT is the standard thread for the G-series, and G (BSPP) or NPT are catalogue options selected by code, so order the suffix that matches your pipework.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30008ALJC3WT AirTAC Filter Regulator, NPT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008ALJC3WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.