verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um

The AirTAC GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$61.92 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um

The GFR30008ALJF2WTK is an AirTAC GFR300 filter regulator: it removes water and particulate from compressed air and holds a set downstream pressure, in one body. This configuration is built around a 1/4 in NPT port, carries the 5 um filter element (the finer of the two published grades), drains condensate automatically, and is the low-pressure regulator type. A square pressure gauge reading in psi is fitted, and a reverse/check valve is installed. The polycarbonate bowl lets you see the condensate level at a glance, and no mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans four sizes (200, 300, 400 and 600) with ports from 1/8 to 1 in, and options for thread (PT is the standard; G and NPT are order options), drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um optional), gauge scale and bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing and datasheet figures for your application before ordering.

GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um Technical Specifications

ModelGFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um
SeriesGFR300 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um Is Used

valve

Coating and spray lines

Feeding spray guns and atomizing nozzles on a finishing line, where the 5 um element keeps particulate out of the finish and the low-pressure type holds a gentle, steady setting at the gun.

conveyor_belt

Packaging machinery

Regulating the supply to sealing jaws and pick-and-place cylinders on a packaging line, with the automatic drain keeping condensate out of the actuators without manual attention.

science

Laboratory and test-bench air

A bench supply feeding instruments and small pneumatic actuators, where a set low pressure plus fine 5 um filtration protects sensitive equipment downstream.

Is the GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um the Right Unit?

The choices on this unit are fixed by the code: size 300 with a 1/4 in NPT port, 5 um filtration, automatic drain, low-pressure regulation, square psi gauge, reverse/check valve fitted, no bracket. If you are still selecting within the G-series, step through sizes 200, 300, 400 and 600 to match the port and flow path you need; choose the 5 um element where downstream equipment needs finer air than the standard 40 um; pick automatic drain where the unit cannot be drained by hand on a schedule. Thread here is NPT; PT is the standard and G (BSPP) is available to order. Because flow is published as curves rather than a single rating, and the low-pressure type's adjustment range is not published as a single figure either, send us your application details and we will confirm sizing and datasheet figures before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and the full datasheet figures for the GFR300 at 1/4 in NPT on request.

The A code means condensate is expelled from the polycarbonate bowl automatically, without anyone having to drain it by hand on a schedule. That suits units mounted in awkward or unattended positions. Manual and differential-pressure drain versions are available in the same size if you prefer a different arrangement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30008ALJF2WTK AirTAC Filter Regulator NPT1/4 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008ALJF2WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.