The AirTAC GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$39.92 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um

The AirTAC GFR30010LJC2WT is a 300-size filter regulator: it removes water and particulate from compressed air and then regulates downstream pressure, all in one body. This configuration is the low-pressure type, built for circuits that hold a lower regulated setpoint than a standard unit. It carries a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a round pressure gauge scaled in psi so the setpoint can be read and adjusted directly. The polycarbonate bowl suits the 300 size, the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C, non-freezing. It is supplied without a mounting bracket and without a reverse/check valve.

This is a genuine AirTAC part from the G-series filter-regulator line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in and PT, G or NPT threads. Drain types, 40 um or 5 um elements, gauge styles and scales, brackets and check valves are all catalogue options across the range. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure against your application before ordering.

GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um Technical Specifications

ModelGFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um
SeriesGFR300 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT3/8" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-10 (two-unit set)

Where the GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um Is Used

settings_input_component

Packaging machine film-sealing bars

Sealing jaws and film-tension cylinders on packaging lines often run at low regulated setpoints. This low-pressure filter regulator cleans the supply to 5 um and holds the reduced pressure the sealing circuit was set up for, with the psi gauge making the setting easy to check during changeover.

precision_manufacturing

Pneumatic clamping on CNC fixtures

Workholding clamps on machining centres need clean air and a steady, moderate clamping pressure. Filtering to 5 um protects the clamp valves and cylinders from fine particulate and condensed water, while the regulator holds the clamp force the fixture was designed around.

science

Laboratory and test-rig air supply

Bench-scale test rigs and lab pneumatic circuits frequently need a lower, stable supply pressure and very clean air. The 5 um element and low-pressure regulation suit instrumented setups, and the differential-pressure drain keeps condensate off the circuit during continuous runs.

Is the GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um the Right Unit?

Start with the port: this unit is 3/8 in NPT, so match it to the line size your circuit already runs or step up a size if your flow demand sits near the top of a smaller port. Because published flow data is a set of curves rather than one rated number, send us your application conditions and we will confirm the right size before you order. The 5 um element in this unit is the finer grade; choose it when downstream valves, cylinders or instruments are sensitive to fine particulate, and stay with 40 um where coarser protection is enough. Drain is differential-pressure, which suits steady-flow duty; ask about automatic or manual drain variants if your flow pattern or access needs differ. The low-pressure regulator type is intended for circuits holding lower setpoints - its exact adjustment range is not published in the catalogue, so confirm it with us for your setpoint. The round gauge is scaled in psi; square embedded gauges and MPa or bar scales are alternatives in the range. Thread is NPT here, with PT and G available as order options, and a mounting bracket can be added if you need panel or wall fixing.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um FAQ

AirTAC publishes flow for the G-series as curves, not as a single rated figure, so there is no one rated flow number we can quote. Send us your inlet pressure, setpoint and expected air demand and we will confirm the correct size from the datasheet curves before you order.

The W code in the model sets the 5 um element, the finer of the two catalogue grades (40 um is standard), which suits sensitive downstream components. The blank drain position is the differential-pressure drain: it discharges collected condensate automatically as air flows through, with no manual intervention needed. Automatic (A) and manual (M) drain versions are available in the range if your duty or access suits them better.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30010LJC2WT AirTAC Filter Regulator 3/8 in NPT, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30010LJC2WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.