verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge

The AirTAC GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$63.74 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge

The AirTAC GFR400-10F1T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 unit is fitted with 3/8 in NPT ports, the standard 40 um filter element, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. The set pressure is adjusted across 0.15-0.9 MPa (20-130 psi) and read on the embedded square gauge, which is scaled in MPa. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits this size; a mounting bracket is included.

This is a genuine AirTAC part from the GFR400 series, one of four sizes (200/300/400/600) with port options from 1/8 to 1 inch. Across the range you can order a 5 um element (code W), automatic or manual drain instead of the differential-pressure drain, a psi or bar gauge scale, an external round gauge, G (BSPP) or NPT threads in place of the PT standard, and a low-pressure regulator type. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge Technical Specifications

ModelGFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated air to the tool-change and clamping circuits of a CNC machining centre, with the 40 um element protecting directional valves from particulate and the regulator holding a steady set pressure at the machine.

conveyor_belt

Packaging line actuator supply

Sits at the drop point feeding cylinders and grippers on a carton packaging line, removing condensate picked up in the distribution piping and keeping actuator speed consistent through the 0.15-0.9 MPa adjustment range.

settings_input_component

Pneumatic panel branch regulation

Installed as a branch regulator in a plant air panel, dropping header pressure to the level one machine section needs, with the differential-pressure drain handling condensate and the MPa-scaled square gauge giving a local set-point readout.

Is the GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge the Right Unit?

Start with the port and size step: this unit is size 400 with 3/8 in NPT ports; step up or down (200/300/400/600) if your line runs larger or smaller piping, and size against required flow rather than port alone. Choose the drain: the differential-pressure drain on this unit is maintenance-light, the automatic drain (code A) empties continuously, and the manual drain (code M) is for supervised installations. The 40 um element fitted here is the standard grade; specify 5 um (code W) where finer particulate removal is needed downstream. The square gauge on this unit reads in MPa; psi and bar scales and an external round gauge are order options. Threads are NPT on this unit; G (BSPP) is available, with PT as the catalogue standard. A mounting bracket is included; on GF/GR/GL/GFR units the J code deletes it.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the datasheet curve and sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge FAQ

AirTAC publishes flow for the GFR series as performance curves rather than a single rated figure, so we do not quote a flow number here. Send us your application details and we will confirm the datasheet curve for the GFR400 at your operating conditions before you order.

This unit carries the default differential-pressure drain, which discharges collected condensate from the polycarbonate bowl when the pressure differential across the 40 um element rises sufficiently. If you prefer, the same GFR400-10 size can be ordered with an automatic drain (code A) or a manual drain (code M); note that the regulation range differs by drain type: 0.15-0.9 MPa (20-130 psi) for the automatic and differential-pressure drains, and 0.05-0.9 MPa (7-130 psi) for the manual drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400-10F1T AirTAC Filter Regulator NPT3/8 with Gauge

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010F1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.