verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure

The AirTAC GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$73.89 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure

The AirTAC GFR400-10LJ is a filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This 400-size unit is fitted with a 3/8 in NPT port. It is the low-pressure (L) type, so it is intended for circuits where the working pressure sits below the standard regulator band - the exact adjustment range for this variant is confirmed on request. The 40 um filter element is the standard grade, the differential-pressure drain bleeds collected condensate automatically as flow passes through, and the round external gauge (MPa scale) gives a clear local pressure readout. A reverse/check valve is fitted to hold downstream pressure if the upstream supply drops, and the unit is supplied without a mounting bracket.

This is a genuine AirTAC part from the GFR filter-regulator family, which spans the 200, 300, 400 and 600 sizes with port options from 1/8 in to 1 in, manual or automatic drain variants, a 5 um (W) element option, gauge and scale choices, and PT, G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details against your application before ordering.

GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure Technical Specifications

ModelGFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure Is Used

valve

Low-pressure pneumatic clamping circuit

On a fixture or jig line where clamps are held at reduced pressure to avoid marking the workpiece, the low-pressure type regulator sets the holding pressure while the 40 um element keeps contaminants out of the clamp cylinders, and the check valve holds the clamp if supply pressure dips.

conveyor_belt

Packaging-line cylinder air supply

Feeding the pick-and-place and sealing cylinders on a packaging conveyor, this 3/8 in filter regulator cleans the shop air of water and particulate, holds a steady set pressure for consistent motion, and its differential-pressure drain clears condensate as the line runs.

science

Laboratory and test-bench air supply

On a lab bench or test rig running instruments and small actuators at reduced pressure, the low-pressure regulator gives finer control in the lower band, the round MPa gauge provides a local readout, and the 40 um filter protects sensitive downstream devices.

Is the GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure the Right Unit?

Start with the port step: this unit is the 400 size with a 3/8 in NPT port; if your line needs more or less flow capacity, the GFR family steps through 200/300/400/600 with ports from 1/8 in to 1 in. Drain choice matters: differential-pressure (this unit) drains with flow, automatic (code A) drains on its own cycle, and manual (code M) needs an operator - the manual variant also widens the standard adjustment range downward. The 40 um element here is the standard grade; specify W for the 5 um element where finer filtration is needed. Gauge options are the embedded square gauge or this external round gauge, with MPa, psi or bar scales. Thread is NPT here; PT is the catalogue standard and G (BSPP) is also orderable. Brackets are optional (this unit omits one, code J), and the K code adds the reverse/check valve fitted here. Note this is the low-pressure (L) type - its adjustment range is not published in the standard table, so confirm it with us. Flow for the whole series is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one rated flow number we can quote. Send us your application details and we will confirm the flow and sizing from the datasheet on request before you order.

L marks the low-pressure regulator type, intended for circuits where the working pressure sits below the standard adjustment band; the exact adjustment range for the low-pressure variant is not published in the standard table, so we confirm it on request. The rest of this code decodes as: 3/8 in NPT port, differential-pressure drain, 40 um element, no bracket, round gauge on the MPa scale, reverse/check valve fitted, and NPT thread.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400-10LJ AirTAC Filter Regulator, NPT 3/8, Low Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010LJC1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.