AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um

The AirTAC GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$85.58 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um

The AirTAC GFR40010ALC2WTK is a GFR400-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries the 5 um filter element (code W, against the 40 um standard), an automatic drain that discharges collected condensate without manual attention, and a round gauge reading in psi. The L in the code marks the low-pressure regulator type, and a reverse/check valve is fitted. The port is NPT3/8 (3/8 in), the bowl on this 400 size is polycarbonate (PC), the unit is rated to 1.0 MPa (145 psi) maximum inlet and -5 to 70 C (non-freezing), and a mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, in PT (the standard), G and NPT threads, with manual, automatic or differential-pressure drains, 40 um or 5 um elements, gauge and scale choices, and optional brackets. Flow for this model is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um Technical Specifications

ModelGFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um Is Used

air

Pneumatic paint-spray lines

Feeding spray guns in a finishing booth: the 5 um element strips water and particles that would spoil the finish, the low-pressure regulator lets the painter dial in the gun supply, and the automatic drain keeps condensate out of the line.

precision_manufacturing

Packaging machine actuation

Filtered, regulated air for the cylinders on a carton-sealing or filling line, where the round psi gauge lets the setter read supply at a glance and the fitted reverse/check valve guards the downstream circuit.

science

Laboratory test-rig air supply

Clean, low-pressure regulated air for bench test rigs and pneumatic instrumentation panels, where the 5 um grade protects sensitive components and the automatic drain suits an unattended rig.

Is the GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um the Right Unit?

Choices you can decode from the code: size 400 with a NPT3/8 port for the air line; drain type - automatic here, chosen over manual (periodic draining) or differential-pressure; filter grade - 5 um here for finer protection versus the 40 um standard; gauge - a round psi scale here, with the embedded square gauge and MPa/bar scales also available; thread - NPT here while PT is the AirTAC standard and G is also orderable; and a mounting bracket is included. The low-pressure (L) regulator type is intended for circuits working below standard mains pressures - the exact adjustment range is not published, so confirm it with us before ordering.

Flow is published as curves, not a single rating, so send us your application's air demand and line pressure and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Send us your application's air demand and line pressure and we will confirm the flow from the datasheet on request.

The 40 um element is the standard grade for general plant air. The 5 um element fitted here is the finer catalogue option for work such as spray finishing, instrumentation or close-tolerance pneumatic components. The W in the code selects the 5 um grade on this family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010ALC2WTK AirTAC Filter Regulator NPT3/8 5um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010ALC2WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.