verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure

The AirTAC GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$85.85 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure

The AirTAC GFR400 series combines water and particulate filtration with pressure regulation in a single body, and this configuration, GFR40010ALC3TK, is the size 400 unit with a 3/8 in NPT port. It carries a 40 um standard filter element, an automatic drain that expels collected condensate without manual attention, and a low-pressure regulator type for circuits that run below standard regulator settings. A round pressure gauge scaled in bar is fitted so the set pressure is visible at the unit, and a reverse/check valve is included to hold downstream pressure when the upstream supply is lost. The polycarbonate bowl suits the 400 size, a mounting bracket is included, the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, PT as the standard thread and G (BSPP) or NPT as order options, a choice of differential-pressure, automatic or manual drain, a 5 um (code W) element alternative to the standard 40 um, and gauge or bracket variations. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.

GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure Technical Specifications

ModelGFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure Is Used

precision_manufacturing

Pneumatic press and clamp circuits on an assembly line

Feeding air to clamping fixtures and light press cylinders on a production line, where the unit filters line water and particulate, holds a set pressure downstream of the check valve, and drains condensate automatically between shifts.

science

Air supply to a laboratory or pilot-plant process skid

Conditioning shop air before it enters a bench-scale process skid or test rig, giving the skid a visible bar-scaled setpoint, a 40 um element to protect sensitive instruments, and automatic drainage so the unit can sit inside an enclosure unattended.

view_module

Packaging machine air preparation at a low set pressure

Preparing air for the vacuum, ejector and actuator circuits of a packaging machine that runs at reduced pressure, where the low-pressure regulator type matches the machine's operating band and the automatic drain keeps condensate out of the valve manifold.

Is the GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure the Right Unit?

Size 400 with a 3/8 in NPT port is the mid-to-large step of the GFR range; step up to size 600 or down to 300/200 according to the flow your line needs, since larger sizes carry larger ports and more flow capacity. This unit is already specified with the automatic drain, which suits unattended or hard-to-reach installations; manual drain and differential-pressure drain are the alternatives in the family if you prefer condensate removal tied to pressure drop or by operator routine. The 40 um element is the standard grade; specify the W variant for 5 um where downstream equipment needs finer filtration. The fitted round gauge reads in bar; square embedded gauges and MPa or psi scales are the other catalogue choices. NPT is the thread on this unit; PT (standard) and G (BSPP) are available to order, and the mounting bracket is included.

Because flow for the G series is published only as curves and not as a single rated number, we do not quote a flow figure here. Send us your application details and we will confirm sizing against the datasheet curves before you order. The low-pressure regulator type on this unit is intended for circuits below standard regulator settings; its exact adjustment range is not published in our sheet, so confirm it with us on request.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure FAQ

AirTAC publishes G-series flow only as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number here. Send us your application flow and pressure and we will confirm sizing against the datasheet curves on request before you order.

The A in the code GFR40010ALC3TK specifies an automatic drain, which expels collected condensate by itself and suits unattended or enclosed installations. The GFR family also offers manual drain and differential-pressure drain as decodable options, and the drain choice affects the regulator adjustment range, so confirm the details with us on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010ALC3TK AirTAC Filter Regulator NPT3/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010ALC3TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.