The AirTAC GFR40015MLC2W AirTAC Filter Regulator PT1/2, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR40015MLC2W is an AirTAC GFR400 filter regulator: a single body that removes water and particulate from compressed air and regulates downstream pressure. This configuration is the size 400 unit with a 1/2 in PT port, a 5 um filter element (the finer of the two published grades), a manual drain for the PC bowl, and the low-pressure regulator type. A round pressure gauge reading in psi is fitted, a mounting bracket is included, and no reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, a choice of 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, standard or low-pressure regulation, gauge and scale options, and G (BSPP) or NPT threads as order variants alongside the PT standard. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR40015MLC2W AirTAC Filter Regulator PT1/2, 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-15 (two-unit set) |
A job-shop machining cell running air-actuated clamps on its fixtures uses this filter regulator to deliver cleaned air at a steady, low set pressure, with the psi gauge giving the operator a direct reading at the clamp circuit.
A test bench or lab rig with sensitive pneumatic instruments takes point-of-use air through this unit: the 5 um element strips fine particulate and water before the regulator sets the low working pressure the bench needs.
A packaging line's cylinder-actuated sealing and forming stations draw from a drop leg fitted with this filter regulator, keeping moisture and debris out of the valves while the low-pressure type holds the gentle setting those actuators require.
Size 400 with a 1/2 in PT port suits lines plumbed at that port size; step up or down a size if your flow demand or existing pipework differs. The 5 um element (code W) is the finer published grade versus the 40 um standard - choose it where downstream valves and instruments tolerate less particulate. This unit has a manual drain, so the bowl must be drained by hand on a routine; an automatic or differential-pressure drain variant removes that task if the installation is not attended. The round gauge supplied reads in psi; square embedded gauges and MPa or bar scales are the other published options. PT is the standard thread; G (BSPP) and NPT are available to order as specifications, not delivery promises. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR400 series as curves, not as a single rated figure, so no rated flow number is stated here. Send us your line pressure, port size and downstream demand and we will confirm the sizing from the datasheet on request before you order.
The M in the code GFR40015MLC2W means the PC bowl is drained by hand, which suits attended installations on a maintenance routine. The published alternatives for this family are an automatic drain (code A) and the differential-pressure drain, which is the default; the regulator adjustment range also differs by drain type, so we can confirm the exact figure for the variant you need on request.