verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge

The AirTAC GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$117.53 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge

The AirTAC GFR600-25 is a size-600 filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This configuration carries a 5 um filter element (the finer W grade, versus the 40 um standard), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, and a fitted reverse/check valve that holds downstream pressure if the upstream supply drops. The port is PT1 (1 in, PT thread standard). Outlet pressure is set with the fitted external round gauge, which reads in psi; the regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. At size 600 the bowl is aluminium alloy, and no mounting bracket is included with this code.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of PT, G or NPT thread, manual, automatic or differential-pressure drains, 40 um or 5 um elements, gauge and scale options, and an optional low-pressure regulator type. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and check the curve against your application before ordering.

GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge Technical Specifications

ModelGFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge
SeriesGFR600 filter regulator
Port sizePT1" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 5 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge Is Used

factory

Central plant air drop for a production hall

Installed at a large-diameter air drop feeding a production hall, the unit filters water and particulate from the main supply and holds a steady regulated pressure for the tools and actuators served by that drop, while the check valve keeps downstream circuits pressurised during compressor unload or brief supply dips.

conveyor_belt

Air supply for a packaging and case-sealing line

On a packaging line with case erectors, tape heads and pneumatic diverters, the 5 um element protects cylinders and valve manifolds from finer contamination, the regulator holds consistent working pressure so seal and clamp actions stay repeatable, and the differential-pressure drain keeps condensate moving out without daily manual attention.

science

Instrument air for a test bench or lab process

Feeding pneumatic test benches, air-bearing fixtures or lab process panels, the unit cleans the shop supply down to 5 um and trims it to the pressure the bench needs, the psi gauge gives operators a direct local readout, and the check valve prevents backflow from the bench into the shop ring main.

Is the GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge the Right Unit?

Size 600 with a PT1 (1 in) port is the largest step in the GFR range, so size the unit against the air demand of the circuit rather than the pipe size alone - a unit that is too small for the flow will drop pressure across the element. Choose the drain to match access: this code uses the differential-pressure drain, which needs no daily attention but relies on flow to purge; a manual drain suits attended installations and an automatic drain suits unattended ones. The 5 um W element here is the finer of the two published grades (40 um standard) - pick 5 um where downstream equipment is sensitive to finer particulate. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue options. The fitted reverse/check valve holds downstream pressure through supply dips. Thread is PT as standard; G and NPT are order options. No bracket is included with this code, so plan the mounting. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Ask us and we will confirm the datasheet and read the flow curve for your inlet pressure and set pressure so you can size the unit correctly before ordering.

The W in the code GFR60025JC2WK selects the finer 5 um filter element instead of the 40 um standard, and the K selects a fitted reverse/check valve that holds downstream pressure if the upstream supply drops. The drain is the differential-pressure type (the default): it purges collected condensate automatically when the pressure differential across the element is high enough, with no manual draining required.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25 AirTAC Filter Regulator 1 in PT, 5 um, psi Gauge

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025JC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.