The AirTAC GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$117.83 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um

The AirTAC GFR600-25 is a size-600 filter regulator: it removes water and particulate from compressed air and holds a steady downstream pressure in a single body. This configuration is fitted with a 1 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element rises, and an embedded square pressure gauge scaled in MPa. A reverse/check valve is fitted, and the unit is supplied without a mounting bracket. The size-600 bowl is aluminium alloy, and the maximum inlet pressure is 1.0 MPa (145 psi) with a working temperature range of -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, PT, G and NPT threads, manual, automatic or differential-pressure drains, a 5 um (W) filter element option, and gauge scale choices. Rated flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application on request.

GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um Technical Specifications

ModelGFR600-25 AirTAC Filter Regulator NPT1 in, 40 um
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um Is Used

factory

Main plant air drop regulation

Installed at the take-off from a compressor room header to condition and regulate the air feeding an entire production floor, where a 1 in line serves multiple downstream circuits.

precision_manufacturing

CNC machining cell air supply

Feeding filtered, regulated air to the pneumatic clamps, tool-change cylinders and chip-clearing blasts on a machining centre fed by a high-capacity shop air main.

conveyor_belt

High-volume packaging line supply

Conditioning the air that drives case-erectors, baggers and palletiser cylinders on a packaging line running large-bore actuators from a 1 in distribution leg.

Is the GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um the Right Unit?

Size 600 with a 1 in port is the largest step in the GFR range, so start there when the line's required flow is high and step down to 400, 300 or 200 where it is not. The regulation range of this standard-type unit is 0.15-0.9 MPa (20-130 psi). Drain choice matters: the differential-pressure drain fitted here needs no operator attention, while automatic (A) and manual (M) versions are orderable. The 40 um element suits general plant air; specify the W code for 5 um where downstream equipment needs finer filtration. The square gauge is fitted and scaled in MPa; psi or bar scales and an external round gauge are options. This unit is supplied without a bracket (J), and the T code gives NPT threads where PT is the standard and G is also orderable.

One honest note on sizing: AirTAC publishes GFR flow as curves, not a single rated number, so send us your flow and pressure conditions and we will confirm the correct size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um FAQ

AirTAC publishes flow for the GFR series as performance curves rather than a single rated figure, so no single number can be quoted here. Tell us your line pressure, set pressure and expected air demand, and we will confirm the flow and the correct sizing against the datasheet on request before you order.

This configuration has no drain code, which means the differential-pressure drain: it discharges collected condensate automatically whenever the pressure drop across the 40 um element rises to a set level, with no operator input. If your maintenance routine prefers it, automatic (A) or manual (M) drain versions of the same size are orderable.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25 AirTAC Filter Regulator NPT1 in, 40 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025JF1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.