verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600-25T AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600-25T AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeNot fitted
  • ThreadNPT
$100.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25T AirTAC Filter Regulator 1 in NPT

The GFR600-25T is an AirTAC GFR-series filter regulator: water and particulate removal plus downstream pressure regulation in a single body. This size-600 unit is fitted with a 1 in NPT port, the 5 um filter element (code W) for finer filtration than the standard 40 um grade, and a differential-pressure drain that bleeds accumulated condensate automatically whenever the pressure differential across the element is high enough. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi). No gauge is fitted on this variant, and no mounting bracket is included. The bowl on size-600 units is aluminium alloy, and the maximum working (inlet) pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with manual or automatic drains, a 40 um or 5 um element, an embedded square or external round gauge in MPa, psi or bar scale, a reverse/check valve, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so contact us and we will confirm the datasheet figures for your application on request.

GFR600-25T AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600-25T AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25T AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 5 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25T AirTAC Filter Regulator 1 in NPT Is Used

factory

Main air supply for a packaging hall

Dropping the 1 in NPT port into the main line feeding a packaging hall: the element strips water and fine particulate before the air reaches the distribution manifold, and the regulator holds a steady header pressure for every machine tapped off it.

conveyor_belt

Conveyor drive air preparation

Mounting ahead of the pneumatic cylinders and actuators on a conveyor or sorting line: clean, dry, regulated air keeps the drive and stopper cylinders cycling consistently through long production runs.

valve

Protecting control valves on a process skid

Placed upstream of pneumatic control valves and positioners on a process skid: the 5 um element screens out fine debris that would score valve seats, while the regulator holds the set pressure the valve actuators were sized for.

Is the GFR600-25T AirTAC Filter Regulator 1 in NPT the Right Unit?

Size and port are the first decision: step up through 200, 300, 400 and 600 as the required flow and pipe size grow - this unit is already at the top of the range with its 1 in NPT port. Drain type is a real choice where a bowl is fitted: differential-pressure (this unit) needs no attention at moderate duty, automatic drain suits unattended installations, and manual drain suits low-condensate duty. Filter grade is 40 um standard or 5 um (code W, as here) when finer protection is needed downstream. Units with a regulator can carry an embedded square gauge or an optional external round gauge in MPa, psi or bar scale - this variant has none fitted, so add one if local pressure indication is required. Thread is PT as standard, with G and NPT as order options; this unit is NPT. A bracket is optional on GFR units and is not included here.

Flow for this family is published as curves, not as a single rated number, so we cannot quote a rated flow figure. Ask us to confirm sizing against your application from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600-25T AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow number. Contact us with your line size and consumption and we will confirm the datasheet flow figures for this 1 in NPT, size-600 unit on request.

The W in the code GFR60025JNWT selects the optional 5 um filter element for finer particulate removal than the standard 40 um grade - useful when protecting sensitive valves or instruments downstream. The drain is the differential-pressure type: it discharges collected condensate automatically when the pressure differential across the element rises, with no manual draining required in normal operation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25T AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025JNWT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.