verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um

The AirTAC GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$119.01 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um

The AirTAC GFR600-25T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 600-size unit is fitted with a 1 in NPT port, a 5 um filter element (code W), a differential-pressure drain that bleeds condensate automatically as flow passes through, and a low-pressure regulator type for applications that work at reduced set points. The aluminium alloy bowl suits the larger 600 frame, and the embedded square gauge reads in MPa so you can see and set the downstream pressure at a glance. A reverse/check valve is fitted to hold downstream pressure if the supply drops, and the mounting bracket is included.

This is a genuine AirTAC part, not a copy. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options include manual or automatic drains, a 40 um standard element, alternative gauge scales (MPa, psi or bar) and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm sizing or any datasheet figure for your application before ordering.

GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um Technical Specifications

ModelGFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 5 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um Is Used

valve

Large pneumatic press air prep

Feeds filtered, regulated air to a big pneumatic press or clamp cylinder circuit, with the 5 um element protecting the directional valve and the check valve holding the set pressure if the supply dips.

factory

Bottling line actuator supply

Sits at the head of a bottling or canning line's air drop, conditioning the supply for grippers, stoppers and diverter actuators while the MPa gauge lets the maintenance team verify set points at a glance.

precision_manufacturing

CNC machining cell air drop

Conditions the shop-air feed into a CNC machining cell, removing water and fine particles before tool-change and clamping circuits and keeping the downstream pressure stable under varying demand.

Is the GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um the Right Unit?

Start with the port: this unit is 1 in NPT, so match it to the line size or step up a size if your flow demand is high. If your working pressure sits well below the standard regulator band, the low-pressure (L) type in this code is the right choice; we can confirm its exact set-point band from the datasheet on request. The 5 um element (W) suits air that feeds sensitive valves, cylinders or instruments; the 40 um standard element is fine for general shop-air protection. Drain choice matters: differential-pressure (fitted here) needs no attention during operation, while manual and automatic drains are available as alternatives. Gauge scale can be MPa, psi or bar, and threads can be ordered in PT (standard), G or NPT. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number that is not in the datasheet. Send us your application details and we will confirm the flow curve and sizing for this 1 in NPT unit on request.

The W code in GFR60025LF1WTK selects the 5 um filter element instead of the 40 um standard, which suits air feeding sensitive valves and instruments. The blank drain position is the differential-pressure type: it bleeds accumulated condensate automatically as air flows through, with no manual intervention needed during operation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25T AirTAC Filter Regulator 1 in NPT, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025LF1WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.