verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$129.47 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR60025ALF1TK is a size-600 GFR filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is built around a 1 in NPT port for high-flow main lines, an automatic drain that expels collected condensate without manual attention, a 40 um standard filter element, and the low-pressure regulator type for circuits that run well below standard line pressure. It also carries a reverse/check valve and a square pressure gauge scaled in MPa, and includes a mounting bracket.

This is a genuine AirTAC part in the GFR family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, standard or low-pressure regulation, gauge and thread options, and reverse-valve variants. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR60025ALF1TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Main air supply for a bottling plant

Installed at the 1 in header feeding a bottling hall, it strips water and debris from the compressed air and holds a steady low regulated pressure to the filler and capper actuators, with automatic drainage keeping condensate off the floor.

conveyor_belt

Conveyor diverters in a distribution centre

Mounted on the branch feeding pop-up diverters and stop-gate cylinders on a parcel conveyor, it delivers clean, regulated air so the divert strokes stay consistent through each shift.

tune

Low-pressure circuit on a textile air-jet loom

Placed on the auxiliary low-pressure line of a weaving shed, its low-pressure regulator type suits circuits that run well below standard line pressure, while the 40 um element protects the loom's pneumatic valves from water and grit.

Is the GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Step up or down through the GFR sizes (200/300/400/600) against the port and flow your line needs; this unit sits at the top of the range with a 1 in NPT connection. Choose the drain to suit access: automatic (as here) for unattended condensate removal, manual for periodic service, or differential-pressure as the default. Filter grade is 40 um standard or 5 um with the W code; gauges come as the embedded square type (MPa, psi or bar scale) or an optional external round gauge; thread is PT as standard with G and NPT as orderable options; brackets can be included or omitted (J).

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so send us your application details and we will confirm the right size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your line pressure and the equipment you are feeding, and we will confirm the flow and sizing against the datasheet on request before you order.

The A code in GFR60025ALF1TK means the bowl drains condensate automatically instead of waiting for a manual blowdown, which suits unattended plant rooms. The L code selects the low-pressure regulator type, intended for circuits that run below standard line pressure; the exact adjustment range for this type is not published in our sheet, so we confirm it on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025ALF1TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025ALF1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.