The AirTAC GFR60025JF2TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR60025JF2TK is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, an embedded square gauge reading in psi, and a built-in reverse (check) valve that holds downstream pressure when the upstream supply is lost. The 600-size bowl is aluminium alloy, and no mounting bracket is supplied with this code.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of PT, G or NPT threads, differential-pressure, automatic or manual drains, a 40 um standard or 5 um (W) filter element, square or round gauges with MPa, psi or bar scales, a low-pressure regulator type and a reverse valve option. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request.
| Model | GFR60025JF2TK AirTAC Filter Regulator 1 in NPT |
|---|---|
| Series | GFR600 filter regulator |
| Port size | PT1" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| 25 | Port size PT1". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · PT1" · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-25 (two-unit set) |
Installed at the main air drop feeding a packaging hall, the GFR60025JF2TK cleans water and scale out of the compressed air and holds a steady regulated pressure to the hall's distribution manifold, with the check valve keeping downstream lines pressurised during compressor unload events.
Mounted ahead of the cylinder banks that divert and stop bottles on a bottling conveyor, this filter regulator keeps moisture and particulate out of the valve stack and gives the line engineer a local psi gauge to set and verify actuation pressure at the machine.
Fitted where the 1 in shop air header enters a CNC machining cell, the unit conditions the supply before it splits to tool-change and clamping circuits, the 40 um element catching pipe-scale carried in from the header and the differential-pressure drain handling condensate without daily manual draining.
Size 600 with a 1 in port sits at the top of the GFR range, so start by matching the port size and expected air demand of the line; if your flow sits near the top of a smaller size, step up to 600 rather than undersizing. This code already fixes several choices: differential-pressure drain (no manual draining routine, and no automatic-drain code needed), 40 um filtration (choose the W code only if 5 um is required), a square psi gauge, a reverse valve, and no bracket. If you need a different drain, grade, gauge scale or a bracket, a different GFR600 code carries it.
Flow for this family is published as curves, not a single rated figure, so we cannot quote a number here. Ask us to confirm the datasheet and check the curve against your application's flow and pressure requirements before ordering. PT is the standard thread; G and NPT are catalogue options ordered by code, and this unit is the NPT version.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Contact us and we will confirm the datasheet and read the flow curve for the GFR600 at your working pressure to check it against your application before you order.
With no drain letter in the code, the GFR60025JF2TK uses the differential-pressure drain, which discharges collected condensate automatically when the pressure drop across the 40 um element rises - no manual routine and no extra drain code. If your application needs a continuously automatic drain or a manual drain, the corresponding GFR600 code carries the A or M option instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.