The AirTAC GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$107.62 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um

The GFR60025MF2T is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation in a single body. This size-600 unit is specified for 1 in NPT ports, carries the standard 40 um filter element, and is fitted with a manual drain, so condensate is released by opening the drain valve rather than automatically. The bowl on this size is aluminium alloy, and the embedded square gauge reads in psi. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator setpoint range is 0.05-0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options include automatic or differential-pressure drains, a 5 um (code W) filter element, MPa or bar gauge scales, an external round gauge, G (BSPP) or NPT threads in place of the PT standard, and reverse/check valve variants. Published flow data appears as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.

GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um Technical Specifications

ModelGFR60025MF2T AirTAC Filter Regulator NPT1, 40 um
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um Is Used

factory

Plant air drop for a packaging hall

Installed at a 1 in branch off the main header, it removes water and debris from the compressed air and lets maintenance set a stable regulated pressure for the packaging machines on that drop. The manual drain suits a hall where operators already walk the line each shift.

conveyor_belt

Conveyor drive and gate cylinders

Feeding the air supply to conveyor gate and stopper cylinders, the unit keeps scale and condensate out of the cylinders and holds the pressure the gate valves were sized for, with the psi gauge giving a visible setpoint at the panel.

local_shipping

Truck and trailer service bay supply

On the shop-air feed to a heavy-vehicle service bay, it filters rust and water from the compressor ring main and regulates the pressure feeding impact tools and inflation equipment, with the aluminium bowl and manual drain handling the wet shop air.

Is the GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um the Right Unit?

Size 600 with a 1 in port is the largest step in the GFR range; step down to 400/300/200 when line size and flow demand are smaller. Drain type is a real choice: this unit is manual drain, while automatic and differential-pressure versions empty the bowl without operator action - pick manual where a scheduled check is part of the routine. The 40 um element is standard; specify the W option for 5 um when finer particulate removal matters. The fitted square gauge reads psi; MPa and bar scales are available, and an external round gauge is optional. Thread here is NPT; PT is the catalogue standard and G (BSPP) is also orderable. A mounting bracket is included. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um FAQ

AirTAC publishes GFR flow data as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure and the flow your equipment needs and we will confirm the correct size from the datasheet on request before you order.

Manual drain means condensate is emptied by opening the drain valve when checked, which suits lines that are inspected on a routine. The same GFR600 body is available with an automatic drain or the default differential-pressure drain - specify the A code or leave the drain position blank when ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025MF2T AirTAC Filter Regulator NPT1, 40 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025MF2T and will confirm price, stock and lead time — usually within 7-8 hours.