The AirTAC GR20006JF1T AirTAC Air Pressure Regulator, NPT1/8 is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The GR20006JF1T is an AirTAC GR200 series air pressure regulator for compressed air, built purely for pressure regulation - it contains no filter, no bowl and no lubricator. This configuration decodes to a 1/8 in NPT port, the standard regulation range of 0.05-0.9 MPa (7-130 psi) and a maximum inlet pressure of 1.0 MPa (145 psi). The F1 suffix means a square pressure gauge with MPa scale is fitted as standard, and the J suffix means no mounting bracket is supplied; as a GR unit it is also panel-mountable. It operates in temperatures from -20 to 70 C, a wider window than the rest of the G-series family.
This is a genuine AirTAC part. The GR family is available in sizes 200, 300, 400 and 600 with a choice of PT, G or NPT thread, optional low-pressure type (up to 0.4 MPa), an optional reverse/check valve, and gauge scale in MPa, psi or bar. Rated flow is published only as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GR20006JF1T AirTAC Air Pressure Regulator, NPT1/8 |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (NPT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Supplied without bracket |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Set a stable, repeatable downstream pressure to a clamp cylinder on a CNC fixture, so workholding force stays consistent across every cycle of the part program.
Feed a controlled pressure to small cylinders and air piloting circuits on a packaging or labelling machine, protecting actuators from upstream pressure swings.
Give lab and pilot-plant test rigs an independently adjustable air supply at the bench, with a local MPa gauge for direct reading of the set pressure.
Start with the port step: GR200 is the smallest size in the range (1/8 in here), and larger sizes 300/400/600 carry larger ports and higher flow capacity - match the size to the air demand of the circuit rather than the pipe alone. Choose the gauge scale you read on site: MPa (fitted here), psi or bar. Thread is NPT in this code; PT is the catalogue standard and G (BSPP) is a orderable option, so pick the one that matches your fittings. Decide whether you need the low-pressure L type (up to 0.4 MPa), a reverse/check valve (K), a mounting bracket, or an external round gauge instead of the embedded square one. Because flow is published as curves and not a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC publishes regulator flow only as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Tell us your application and we will confirm the flow data from the datasheet on request before you order.
F means a square pressure gauge is fitted and 1 sets its scale to MPa. If you prefer psi or bar, or an external round gauge instead of the embedded square one, other gauge codes are available in the same series - just ask.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.