verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GR600 · Air Pressure Regulator

GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in)

The AirTAC GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadG (BSPP)
  • BracketFixing bracket included
$59.74 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in)

The GR60025F2G is an AirTAC GR-series air pressure regulator for compressed air, and regulation is all it does: there is no filter, no bowl and no lubricator in this unit. This configuration is the size 600 body with a G1 (1 in) female port in G (BSPP) thread, a standard regulation range of 0.05-0.9 MPa (7-130 psi), and an embedded square pressure gauge scaled in psi (an external round gauge is available as an option). Maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -20 to 70 C - wider than the rest of the G family, which suits GR units to colder installations. A mounting bracket is included, and the GR600 can also be panel-mounted.

This is a genuine AirTAC part. The GR line spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, optional G (BSPP) or NPT threads in place of the PT standard, a low-pressure type (L) limited to 0.4 MPa, an optional reverse/check valve (K), and gauge scale choices of MPa, psi or bar. Flow for this regulator is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in) Technical Specifications

ModelGR60025F2G AirTAC Air Pressure Regulator, G1 (1 in)
SeriesGR600 pressure regulator
Port sizePT1" (G (BSPP) thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in)

GR600G-series pressure regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR600 · PT1" · 0.05 - 0.9 MPa (7 - 130 psi)
One size downGR400
Line orderFilter first, then regulator, then lubricator

Where the GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in) Is Used

valve

Plant air main pressure station

Settling a stable, reduced pressure at the take-off point of a factory 1 in compressed-air main before it feeds downstream distribution headers and drop lines.

precision_manufacturing

Pneumatic press and clamping fixtures

Holding the set working pressure on the supply to pneumatic press cylinders and clamping fixtures on a machining cell, where repeatable regulation protects the setup.

conveyor_belt

Packaging and conveyor actuation lines

Regulating supply pressure to air cylinders driving packaging machinery, diverters and conveyor stop-gate actuators on a high-throughput packing line.

Is the GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in) the Right Regulator?

Start with the port and size step: GR600 is the largest GR size with a 1 in port, chosen when the line's required flow demands the bigger body - step down to GR300/GR400 with 3/8-1/2 in ports for smaller lines. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. Then set the options that this code carries: gauge scale (this unit is psi; MPa and bar scales exist), thread (PT is the standard; G and NPT are order options), the standard versus low-pressure (L) type, and whether a reverse/check valve (K) is needed. A mounting bracket is included as standard and GR can also be panel-mounted.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in) FAQ

AirTAC publishes GR regulator flow as curves, not as a single rated number, so we do not state a flow figure. Tell us your application and we will confirm the datasheet flow figures for the GR600 at your conditions on request, before you order.

The F2 code on GR60025F2G specifies the embedded square gauge scaled in psi; MPa and bar scales are catalogue alternatives. The G (BSPP) 1 in port is likewise a catalogue option - PT is the standard thread, and NPT is also available to order. Specify the scale and thread you need and we will quote the matching code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GR60025F2G AirTAC Air Pressure Regulator, G1 (1 in)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR60025F2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.