The AirTAC Airtac GAFC Air Service Unit GAFC200C06LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC200C06LN is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/8in port and 590 g mass place it in the compact size class, suited for a single actuator or small jig. The metal bowl is specified by the C code, and the shared specification of 1.0 MPa max pressure and -5 to 70 C applies regardless of bowl material, so confirm it suits your environment.
Air enters the first body where the 40 um element removes solid grain and moisture, and the regulator sets pressure to the lower range of 0.15-0.4 MPa (20-58 psi). The lubricator then adds a metered ISO VG 32 oil mist downstream, so oil never passes back through the regulator seat. No gauge is supplied with this model; the 1/8in gauge connection is there if you add one later.
| Model | Airtac GAFC Air Service Unit GAFC200C06LN |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic clamp on a small assembly fixture, where the lower pressure range protects delicate parts from over-force.
Provide filtered and regulated air to a lab bench valve or a small test rig that requires a gentle, controlled 0.15-0.4 MPa supply.
Run a small pneumatic press or a handheld air tool on a workbench, with the metal bowl standing up to frequent handling.
Choose this GAFC200C06LN when your line needs the lower pressure band of 0.15-0.4 MPa (20-58 psi) and a compact 1/8in port. The metal bowl is a build choice, not a performance upgrade, and the semi-auto drain dumps condensate on pressure drop while the manual drain works on demand. The 40 um element is the standard grade; select the W option for 5 um filtration if your precision valves demand finer particles. The PT thread carries a gauge scale of MPa/psi if you fit a gauge to the 1/8in connection. For oil-free air downstream, omit the lubricator and choose a plain GAFR200-06 filter-regulator instead; the GAL200-06 lubricator is separately orderable.
With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 25 cc drain bowl and a 36 cc oil bowl, and the complete unit weighs 590 g.
The N after the port code means no gauge is supplied with this unit. The GAFC200 body has a 1/8in gauge connection, so you can add a circular gauge later if you need to read the set pressure. The default PT thread uses a gauge scale of MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.