The AirTAC Airtac GAFC Air Service Unit GAFC200C06S is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This two-piece F.R.L. combination pairs a filter-regulator body with a lubricator on a shared T-bracket, so the air is cleaned and set to pressure before a metered oil mist is added downstream. The GAFC200C06S uses a 1/8" port, regulates from 0.15 to 0.9 MPa (20-130 psi), and filters to 40 um with a metal bowl.
Because the filter and regulator share one housing, there is one less inter-unit joint to seal compared with a three-body filter-regulator-lubricator train. The 25 cc condensate bowl and 36 cc oil bowl set the service rhythm, and the 590 g mass means this unit suits a small panel or frame mount rather than being supported by the tubing.
| Model | Airtac GAFC Air Service Unit GAFC200C06S |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic clamp on a benchtop assembly fixture. The 1/8" port and 40 um element keep small cylinders responsive while the regulator holds a stable setpoint.
Supply a small lab bench needing filtered, regulated air for a single test rig or air bearing. The metal bowl suits a cleanroom-adjacent environment where operator visibility is not required.
Power a portable maintenance cart with one air tool or a blow gun. The semi-auto drain dumps condensate on pressure drop, and the 590 g weight keeps the cart mobile.
The GAFC200 is the entry point of the series, with its 1750 L/min flow curve at 0.7 MPa inlet plotted for small actuators and jigs. The metal bowl (C code) is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material, so confirm it suits your surroundings. This model ships with both semi-auto and manual drains, a circular gauge reading MPa/psi on the PT thread, and a 40 um element. The two units are orderable separately as GAFR200-06 and GAL200-06, so a damaged bowl does not force a full replacement. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan a supply near 1.0 MPa if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.
The GAFC200C06S operates from 0.15 to 0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 25 cc, the oil bowl holds 36 cc, and the unit weighs 590 g.
The C in the code specifies a metal bowl instead of the default PC. The catalogue does not publish impact or chemical resistance data, so the choice is about the build environment. Confirm the metal suits your surroundings; the pressure and temperature ratings are identical across all bowl materials.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.