verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC200N06AL

The AirTAC Airtac GAFC Air Service Unit GAFC200N06AL is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight590 g
$71.09 $79.58Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC200-06 bowl, type and element option on one page All GAFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC200N06AL

This AirTAC GAFC200N06AL is a two-piece F.R.L. combination: a nylon-bowl filter-regulator body joined to a lubricator on a shared T-bracket. The 1/8in port size and 590 g mass suit it for compact jigs and single-actuator circuits where space is tight. Air enters the first body, where the 40 um element removes particulates and the regulator sets pressure, then the lubricator meters ISO VG 32 oil mist into the flow last.

The lower-pressure regulator spans 0.15-0.4 MPa (20-58 psi), and the automatic drain clears condensate from the 25 cc bowl without operator attention. A circular gauge is fitted, reading MPa/psi on the PT thread. The 36 cc oil bowl needs refilling less often than the drain bowl, so maintenance visits are driven by the condensate side.

Airtac GAFC Air Service Unit GAFC200N06AL Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC200N06AL
SeriesGAFC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC200N06AL

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/8" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC200N06AL Is Used

precision_manufacturing

Compact Assembly Jigs

Feed a pneumatic press or clamping fixture on a benchtop assembly station. The 1/8in port and 590 g weight mount directly to the jig frame, and the lower-pressure range suits delicate part handling.

science

Laboratory Air Lines

Supply instrument air to a lab bench where a 0.4 MPa ceiling protects sensitive equipment. The automatic drain keeps condensate out of the line during unattended overnight runs.

handyman

Single-Actuator Test Rigs

Power one pneumatic cylinder in a prototype test setup. The compact body and 25 cc drain bowl are sized for intermittent duty, and the gauge lets you verify the setpoint quickly.

Is the Airtac GAFC Air Service Unit GAFC200N06AL the Right Air-Prep Unit?

Choose the GAFC200N06AL when your circuit needs regulated air below 0.4 MPa and you want automatic condensate removal. The nylon bowl is a build choice, not a performance upgrade: the 1.0 MPa (145 psi) max and -5 to 70 C range are identical across PC, metal, and nylon bowls, so confirm the material suits your environment. The L-type range tops out at 0.4 MPa, so if the machine may ever need more pressure, select the S-type instead. The 40 um element handles general shop air; step to the 5 um version for finer filtration. Spares are orderable as GAFR200-06 and GAL200-06. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling, so plan the inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC200N06AL FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 25 cc and the oil bowl 36 cc. Recommended lubricant is ISO VG 32. The unit weighs 590 g.

The A code specifies an automatic drain that expels condensate from the 25 cc bowl without manual intervention. This is ideal for lines that run continuously or in locations where an operator is not always present to check the bowl level.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC200N06AL

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC200N06AL and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.