The AirTAC Airtac GAFC Air Service Unit GAFC200N06ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC F.R.L. combination pairs a filter-regulator with a lubricator on one T-bracket, so the air is cleaned, set to pressure, then oil-misted in the last stage. The nylon bowl holds 25 cc of condensate and the oil bowl 36 cc, with a 1/8in port and 590 g mass suiting small jigs and single actuators.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 40 um element and a circular gauge reading MPa/psi. The automatic drain clears water without operator attention, and the reverse-flow valve is fitted. Max supply is 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and the unit runs from -5 to 70 C.
| Model | Airtac GAFC Air Service Unit GAFC200N06ASK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic clamp on a benchtop assembly jig with clean, regulated, lubricated air at up to 0.9 MPa. The 1/8in port and 590 g mass mount easily on a small frame.
Supply a compact air drill or screwdriver on a repair bench. The 25 cc condensate bowl and 36 cc oil bowl keep maintenance intervals practical for intermittent use.
Drive a small pneumatic test cylinder in a lab rig where consistent pressure matters. The 40 um element and regulator hold the set point as supply varies, while the gauge confirms the setting.
Choose this GAFC200 for a compact 1/8in line feeding one cylinder or a small fixture. The nylon bowl is a build choice, not a performance upgrade, so confirm it suits your environment; the common spec of 1.0 MPa max and -5 to 70 C applies to all bowl materials. The automatic drain suits wet or unattended lines, while the 40 um element handles general shop air; step to the 5 um element only if you need finer filtration for precision devices. PT thread means the gauge scale is MPa/psi, matching most local operators. The lubricator adds ISO VG 32 oil mist last, so if the line must stay oil-free, choose a plain GAFR filter-regulator instead. Spares are the GAFR200-06 and GAL200-06, both orderable separately. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure near 1.0 MPa if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.
This F.R.L. combination works from 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 25 cc, the oil bowl 36 cc, and the unit weighs 590 g.
The K indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. This is an ordering difference only; the unit still functions as a filter-regulator plus lubricator with the same pressure range and port size.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.