verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC200N06ASK

The AirTAC Airtac GAFC Air Service Unit GAFC200N06ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight590 g
$81.99 $91.21Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC200-06 bowl, type and element option on one page All GAFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC200N06ASK

This AirTAC F.R.L. combination pairs a filter-regulator with a lubricator on one T-bracket, so the air is cleaned, set to pressure, then oil-misted in the last stage. The nylon bowl holds 25 cc of condensate and the oil bowl 36 cc, with a 1/8in port and 590 g mass suiting small jigs and single actuators.

The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 40 um element and a circular gauge reading MPa/psi. The automatic drain clears water without operator attention, and the reverse-flow valve is fitted. Max supply is 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), and the unit runs from -5 to 70 C.

Airtac GAFC Air Service Unit GAFC200N06ASK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC200N06ASK
SeriesGAFC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC200N06ASK

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/8" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC200N06ASK Is Used

precision_manufacturing

Precision jig clamping

Feed a single pneumatic clamp on a benchtop assembly jig with clean, regulated, lubricated air at up to 0.9 MPa. The 1/8in port and 590 g mass mount easily on a small frame.

handyman

Small workshop tools

Supply a compact air drill or screwdriver on a repair bench. The 25 cc condensate bowl and 36 cc oil bowl keep maintenance intervals practical for intermittent use.

science

Lab test fixtures

Drive a small pneumatic test cylinder in a lab rig where consistent pressure matters. The 40 um element and regulator hold the set point as supply varies, while the gauge confirms the setting.

Is the Airtac GAFC Air Service Unit GAFC200N06ASK the Right Air-Prep Unit?

Choose this GAFC200 for a compact 1/8in line feeding one cylinder or a small fixture. The nylon bowl is a build choice, not a performance upgrade, so confirm it suits your environment; the common spec of 1.0 MPa max and -5 to 70 C applies to all bowl materials. The automatic drain suits wet or unattended lines, while the 40 um element handles general shop air; step to the 5 um element only if you need finer filtration for precision devices. PT thread means the gauge scale is MPa/psi, matching most local operators. The lubricator adds ISO VG 32 oil mist last, so if the line must stay oil-free, choose a plain GAFR filter-regulator instead. Spares are the GAFR200-06 and GAL200-06, both orderable separately. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure near 1.0 MPa if you need the full output.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC200N06ASK FAQ

This F.R.L. combination works from 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 25 cc, the oil bowl 36 cc, and the unit weighs 590 g.

The K indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. This is an ordering difference only; the unit still functions as a filter-regulator plus lubricator with the same pressure range and port size.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC200N06ASK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC200N06ASK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.