The AirTAC Airtac GAFC Air Service Unit GAFC200N06SWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC200N06SWK is a two-piece F.R.L. combination: a filter and regulator share one body, and a lubricator is joined on the same T-bracket. Air is cleaned and set to pressure in the first unit, then the lubricator adds a metered oil mist last, downstream of the regulator seat. The 1/8in port and 590 g mass suit small jigs or a single actuator, and the quick mounting clamps hold it firmly to a panel or frame.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 5 um element for finer filtration than the standard 40 um grade. The nylon bowl is the build choice here, and the shared specification of 1.0 MPa max and -5 to 70 C applies regardless of material. A circular gauge is fitted, reading in MPa and psi, and the reverse-flow valve is included as a separate ordering option.
| Model | Airtac GAFC Air Service Unit GAFC200N06SWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bench-mounted clamping jig on an assembly line where the 1/8in port and compact 590 g body fit tight spaces. The 5 um element protects fine pneumatic valves from particle wear.
Supply a single laboratory test rig that needs clean, regulated air at a set pressure. The 25 cc condensate bowl handles light moisture from a small compressor, and the gauge lets the operator verify the setpoint.
Operate one small cylinder or air tool on a maintenance cart. The semi-auto drain clears water on each pressure drop, and the lubricator adds oil mist to keep the moving parts running smoothly.
Choose the GAFC200 body for small-bore circuits where the 1/8in port and 25 cc condensate bowl with 36 cc oil bowl keep the unit compact. The nylon bowl is named for this build, but confirm it suits your surroundings since the catalogue gives no material-specific ratings. The 5 um element traps finer particles for precision valves, though it will need more frequent service than a 40 um grade. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use, and the fitted gauge reads MPa and psi on the PT thread. The reverse-flow valve is fitted per the K code, and the two units are orderable separately as GAFR200-06 and GAL200-06. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the inlet pressure close to the maximum if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.
The GAFC200N06SWK operates from 0.15 to 0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and should never be allowed to freeze. The drain bowl holds 25 cc and the oil bowl 36 cc, with a total weight of 590 g. Use ISO VG 32 oil in the lubricator for proper mist generation.
The W code specifies a 5 um element, which traps finer particles than the standard 40 um grade, making it suitable for precision valves or instrument air. The K code adds a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol. The element will need more frequent service than a 40 um grade, and the reverse-flow valve is fitted as an ordering option without changing the basic F.R.L. function.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.