AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC30008ALK

The AirTAC Airtac GAFC Air Service Unit GAFC30008ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$86.35 $95.87Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC300-08 bowl, type and element option on one page All GAFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC30008ALK

This GAFC30008ALK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 1/4in port and 1020 g mass place it in the mid-size class, suited for feeding a single machine station or a small bank of cylinders. It regulates to a lower 0.15-0.4 MPa (20-58 psi) band, with a 40 um element and an automatic drain.

The filter and regulator share one housing, so air is cleaned and set to pressure before the lubricator adds a metered oil mist last. The 60 cc condensate bowl and 98 cc oil bowl set the service rhythm, and with 1.0 MPa (145 psi) max supply, there is about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range. A circular gauge with an MPa/psi scale is fitted, and the reverse-flow (reflux) valve is included.

Airtac GAFC Air Service Unit GAFC30008ALK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC30008ALK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC30008ALK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC30008ALK Is Used

precision_manufacturing

Precision pressure setting

Set a precise 0.3 MPa for a delicate clamping fixture on a CNC machine, where the lower range gives finer adjustment than a standard regulator.

conveyor_belt

Low-pressure conveyor

Feed a light-duty conveyor drive with a controlled 0.25 MPa, keeping the belt tension gentle while the automatic drain handles condensate.

engineering

Bench test rig

Supply a lab test bench with clean, regulated air at 0.35 MPa for valve cycling tests, with the lubricator protecting the test piece.

Is the Airtac GAFC Air Service Unit GAFC30008ALK the Right Air-Prep Unit?

Choose the body and port first: this GAFC300 with a 1/4in port sits between the smaller GAFC200 (1/8in-1/4in, 590 g) and the larger GAFC400 (3/8in-1/2in, 1810 g). The PC bowl is the standard build, and the automatic drain clears condensate without an operator, which suits lines that run unattended. The L type tops out at 0.4 MPa, so if the machine may ever need more than that, step up to the S type (0.15-0.9 MPa). The 40 um element is the default; the gauge reads in MPa/psi on the PT thread. Spares are the GAFR300-08 filter-regulator and the GAL300-08 lubricator, both orderable separately. Since this set adds oil mist, choose a plain GAFR if the downstream line must stay oil-free. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, giving you room to set the regulator without hitting the ceiling.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC30008ALK FAQ

It is a lower-pressure type, regulating from 0.15 to 0.4 MPa (20-58 psi). Max pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g. Use ISO VG 32 lubricant.

The K code specifies a reverse-flow (reflux) valve fitted to the unit. It is shown as a separate pneumatic symbol in the catalogue, and its detailed function is covered on a dedicated page. For this listing, it is an ordering difference to note when selecting the unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC30008ALK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC30008ALK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.