verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC30008LNWK

The AirTAC Airtac GAFC Air Service Unit GAFC30008LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1020 g
$72.21 $80.77Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC300-08 bowl, type and element option on one page All GAFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC30008LNWK

This GAFC30008LNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. The 1/4in port and 1020 g mass place it in the mid-size class, suitable for a single machine station or a small production cell.

The lower-pressure regulator tops out at 0.4 MPa (20-58 psi), while the 5 um element traps fine particles for sensitive equipment. The 60 cc condensate bowl and 98 cc oil bowl set the service rhythm, and the reverse-flow valve is fitted per the K code. No gauge is supplied, so the 1/8in gauge connection is available if you add one later.

Airtac GAFC Air Service Unit GAFC30008LNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC30008LNWK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC30008LNWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC30008LNWK Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a 1/4in line to a pneumatic vise or indexing fixture where the lower pressure range protects delicate workpieces from over-clamping.

engineering

Lab Air Supply

Supply filtered, regulated air to a test bench or calibration rig that requires fine particle removal and a capped 0.4 MPa output.

factory

Light Assembly Station

Run a small screwdriver or parts feeder on a benchtop assembly line, where the 5 um element keeps tiny nozzles clear.

Is the Airtac GAFC Air Service Unit GAFC30008LNWK the Right Air-Prep Unit?

Choose the GAFC300 body when 1/4in ports and a 3500 L/min plotted flow envelope at 0.7 MPa inlet match your line. The L type limits regulation to 0.15-0.4 MPa (20-58 psi), so confirm your actuators never need more than 0.4 MPa. The PC bowl is the standard build; the 5 um element filters finer than the 40 um default, though it will need more frequent service. The semi-auto drain dumps condensate on pressure drops, with a manual override for on-demand draining. The K code adds the reverse-flow valve, and the PT thread carries an MPa/psi gauge scale if you fit one. Spares are orderable as GAFR300-08 and GAL300-08. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC30008LNWK FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 lubricant. The drain bowl holds 60 cc, the oil bowl 98 cc, and the unit weighs 1020 g.

The N after the port code means no gauge is supplied, so you cannot read the set pressure without adding one to the 1/8in gauge connection. The K code indicates the reverse-flow valve is fitted, which the catalogue shows as a separate pneumatic symbol.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC30008LNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC30008LNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.