The AirTAC Airtac GAFC Air Service Unit GAFC30008LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$77.63 $86.56Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC300-08 bowl, type and element option on one page All GAFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC30008LWK

This F.R.L. combination pairs a filter-regulator with a lubricator on a shared bracket, so the air is cleaned and set to pressure in the first body before a metered oil mist is added downstream. The GAFC300 body takes a 1/4in port and weighs 1020 g, with a 60 cc condensate bowl and a separate 98 cc oil bowl.

The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade. A circular gauge is fitted with an MPa/psi scale for the PT thread, and the reverse-flow valve is included as an ordering option.

Airtac GAFC Air Service Unit GAFC30008LWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC30008LWK
SeriesGAFC300 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC30008LWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/4" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC30008LWK Is Used

precision_manufacturing

Precision valve control

Feed a bank of small solenoid valves on a pick-and-place unit where the 5 um element protects fine internal passages and the 0.4 MPa ceiling prevents over-pressuring sensitive actuators.

engineering

Test bench air supply

Supply a calibration fixture that requires a stable, low-pressure air source; the lower-pressure regulator holds the set point while the lubricator adds a controlled oil mist to the test pieces.

factory

Light assembly line

Run a small screwdriver or tightening tool on a bench assembly station, where the 60 cc condensate bowl and 98 cc oil bowl give a reasonable service interval between checks.

Is the Airtac GAFC Air Service Unit GAFC30008LWK the Right Air-Prep Unit?

Choose the GAFC30008LWK when your line needs fine filtration and a capped 0.4 MPa output, such as a precision pneumatic control circuit. The 5 um element suits sensitive valves but will need more frequent service than a 40 um grade, and the semi-auto drain dumps condensate on each pressure drop while the manual drain offers on-demand release. The PC bowl is the standard build choice, and the PT thread carries an MPa/psi gauge scale; confirm the bowl material suits your environment, as the catalogue gives no material-specific ratings. The lubricator is meant to carry ISO VG 32 oil, so if the line must stay oil-free, omit this set and choose a plain GAFR filter-regulator instead. Spare units are orderable separately as GAFR300-08 and GAL300-08. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC30008LWK FAQ

The GAFC30008LWK operates from 0.15 to 0.4 MPa (20-58 psi) with a maximum supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C and must not freeze. The condensate bowl holds 60 cc and the oil bowl holds 98 cc. Use ISO VG 32 lubricant. The complete unit weighs 1020 g.

The K code specifies a reverse-flow (reflux) valve fitted to the unit. The catalogue shows this as a separate pneumatic symbol, and it is an ordering difference to note. The valve is included on this model, so the unit is ready for applications that specify this option.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC30008LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC30008LWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.