The AirTAC Airtac GAFC Air Service Unit GAFC30008LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This F.R.L. combination pairs a filter-regulator with a lubricator on a shared bracket, so the air is cleaned and set to pressure in the first body before a metered oil mist is added downstream. The GAFC300 body takes a 1/4in port and weighs 1020 g, with a 60 cc condensate bowl and a separate 98 cc oil bowl.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade. A circular gauge is fitted with an MPa/psi scale for the PT thread, and the reverse-flow valve is included as an ordering option.
| Model | Airtac GAFC Air Service Unit GAFC30008LWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-08 filter & regulator, GAL300-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of small solenoid valves on a pick-and-place unit where the 5 um element protects fine internal passages and the 0.4 MPa ceiling prevents over-pressuring sensitive actuators.
Supply a calibration fixture that requires a stable, low-pressure air source; the lower-pressure regulator holds the set point while the lubricator adds a controlled oil mist to the test pieces.
Run a small screwdriver or tightening tool on a bench assembly station, where the 60 cc condensate bowl and 98 cc oil bowl give a reasonable service interval between checks.
Choose the GAFC30008LWK when your line needs fine filtration and a capped 0.4 MPa output, such as a precision pneumatic control circuit. The 5 um element suits sensitive valves but will need more frequent service than a 40 um grade, and the semi-auto drain dumps condensate on each pressure drop while the manual drain offers on-demand release. The PC bowl is the standard build choice, and the PT thread carries an MPa/psi gauge scale; confirm the bowl material suits your environment, as the catalogue gives no material-specific ratings. The lubricator is meant to carry ISO VG 32 oil, so if the line must stay oil-free, omit this set and choose a plain GAFR filter-regulator instead. Spare units are orderable separately as GAFR300-08 and GAL300-08. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-08 filter-regulator on that branch instead of the full combination.
The GAFC30008LWK operates from 0.15 to 0.4 MPa (20-58 psi) with a maximum supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C and must not freeze. The condensate bowl holds 60 cc and the oil bowl holds 98 cc. Use ISO VG 32 lubricant. The complete unit weighs 1020 g.
The K code specifies a reverse-flow (reflux) valve fitted to the unit. The catalogue shows this as a separate pneumatic symbol, and it is an ordering difference to note. The valve is included on this model, so the unit is ready for applications that specify this option.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.